Two Relays Vehicle Loop Detector , inductive loop traffic detector
Technical Data
Supply voltage AC | 220V, 110V, 24V, 12V |
Supply voltage DC | 24V, 12V |
Sensitivity | 0.013%-0.1% |
Operating Temperature | -20°C to +70°C |
Storage temperature | -40°C to +85°C |
Frequency Range | 20 kHz to 200 kHz |
Reaction Time | 100ms |
Loop inductance | Ideal: 80μH to 300μH (incl. conn. wiring) |
Loop connection | <5m optimal |
Loop connection wiring | Maximum length 200 meters Twisted at least 20 times per meter |
Dimensions | 37x74x85 mm (WxHxL) |
Net Weight | 250g |
Work Indicator
Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power, this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.
DIP SWITCH and Wire Jumper
DIP1, 2 setting the sensitivity;set the presence output time of relay 1 by DIP3;set the relay2 as presence/pulse output by DIP4; the output time of presence signal set by DIP5;DIP6set the frequency; jumper wire connect to the open end, PIN16 connect to the NO of relay 1. Jumper wire connect to the close end, PIN16 connect to the NC of relay 1
Work Frequency
User can change the loop's work frequency which can avoid the cross talk by the adjacent loop or environment frequency. It offers two styles frequency, set by DIP6