Specifications
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
15000pcs per Month
Delivery Time :
depend on the order quantity
Packaging Details :
the power less than 45kw use Carton, starting from 45kw use Wooden case
Product Name :
7.5kw 10 hp solar pump inverter
Display :
LED+LCD
Output frequency :
50/60hz
Output voltage :
230VAC/400VAC
Warranty :
18 monthes
Application :
water pump
Description

230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

Solar VFD ac and dc input solar pump inverter 380v 4kw 5hp mppt control

Electrical Specifications and Power degree

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS



Advantages:

1, Suitable for single phase pump, three phase pump. Permanent magnet synchronous pump

2, Support PV input and AC input at same time, make system work 24 hours.

3, Built-in MPPT technology with up to 99.9% efficiency.

4, With water level detection function, automatically regulate the pump flow to prevent dryrunning

5, Water full protection function, when the water is full, inverter will stop.

6, Support optional LCD keypad, you can know every parameter's meansing on display,

and you can monitor any 5 group parmaters situation.

7, Support optional GPRS module, you can remotely monitor the system situation.


Accessories:

1. GPRS (support 2g/3g/4g internet)

It supplies water volume monitoring and operation of inverter from anywhere at anytim
It’s convenient to visit real time and historical data via web or Android APP anytime and anywhere.
This easy-to-use platform makes monitoring of solar pump systems simple and convenient,
far reducing operate time and monitoring costs as well.

230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

2. LCD keypad

Standard inverter are with LED keypad,LCD keypad is optional.
LCD keypad can monitor 4 parameters at the same time. LED keypad show one parameter only.
LCD keypad with detailed parameter explain,no need use user manual ,more user friendly.
LCD keypad with copy and update and download function.widely used for government projects and big farms.

230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control


3. Output Reactor

When the distance between inverter and pump is more than 70m, you need use reactor to protect this system.
230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

VFD500-PV 5.5KW 7.5kw 380V inverter picture:
230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

Technical Questions and solutions

1. How to achieve Automatic start after stop?

If it is controlled by keyboard no need to set any parameter. If you want to control by external switch

As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop

2. How to use a float in the water tank to stop the pump if the tank is full?

If your float signal is digital signal Use float switch to short DI 1 and com and P00.06=1

3.Use level probe in the well for protection against dry running?

Set P24.13=30%-40% and P24.14 P24.16 and P23.21

If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and

P41.03-P41.06


FAQ
1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
2. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
the inverter. If needed, we will provide technical support online.
3. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3



Send your message to this supplier
Send Now

230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

Ask Latest Price
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
230VAC 400VAC 7.5kw 10hp 3 Phase Solar Pump Controller VFD MPPT Control

Shenzhen Veikong Electric Co., Ltd.

Verified Supplier
4 Years
shenzhen
Since 2013
Business Type :
Manufacturer, Exporter
Total Annual :
15000000-20000000
Employee Number :
201~500
Certification Level :
Verified Supplier
Contact Supplier