VEIKONG VFD580 servo drive VFD ac drive built in dc reactor 380v 10hp 7.5kw
Features
1. Support AC asynchronous and permanent magnet synchronous motor, servo motor, supports speed, torque and servo position control mode.
2. 15kw and above equipped with built-in DC reactor as standard
3. 37kw and below equipped with built-in braking unit as standard, 45kw-90kw is optional, starting from 110kw is enternal.
4. 90kw and below equipped with brake circuit short-circuit protection function.
5. Support MODBUS-RTU,CAN-Open, ProfiNet. Stronger mode VFD586 supports EtherCat
6.Support 6 kinds of PG card(Incremental PG card, rotary, sin-cos pg card, ABZ close loop pg card, UVW pg card and Tamagawa absolute pg card.
7. Standard motor temperature sensor interface, support PT100, PT1000, KTY84
8. Support LCD keypad, it is easy to monitor and operator.
9. Support STO function
Product specification
Item | Specification | |
Input |
Input voltage | 1phase/3phase 220V:200V-240V 3phase 400V:380V-480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Input filter | SIZE C and above with built in DC reactor | |
Output | Output voltage | 3phase:0~input voltage |
Overload capacity | 150% rated output current for 60s;180% rated output current for 10s;200% rated output current for 2.0s | |
Control |
Control mode | V/f control Sensorless vector control (SVC) Vector control with speed sensor (VC) |
Operating mode | Speed control,torque control(SVC ;VC),position servo | |
Speed range | 1:100(V/f) 1:200(SVC) 1:1000(VC) | |
Speed control accuracy | ±0.5%(V/f) ±0.2%(SVC) ±0.01%(VC) | |
Frequency range | 0.00~600.00Hz(standard) 0.0~2000.0Hz(higher standard) | |
Input frequency resolution | Digital input:0.01Hz or 0.01% Analog input:The maximum frequency is 0.025% | |
Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 180%/0Hz(VC) | |
Torque control accuracy | SVC:5Hz within 8%,5Hz above 5% VC:3.0% | |
Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s | |
Position control | The position command supports internal position, pulse position input, CAN open position command, Ethercat position command (VFD586). Support position full closed loop mode | |
DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault; Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid skipping the voltage fault; | |
Carrier frequency | 1kHz~16kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Special functions | Built-in delay unit, comparison unit and logic unit, etc., two groups of motor parameter switching, software switching output phase sequence, spindle orientation, online identification of motor parameters |
Product picture