IP21 ip65 3 Phase 380v 200kw 250kw VFD Solar Pump Inverter pump controller
VEIKONG is professional manufacturer of solar pump inverter, industrial vfd, soft starter.
VEIKONG VFD500-PV FEATURES: (220V 0.75KW-75KW, 380V 0.75KW-710KW)
1. Operates without grid directly from photovoltaic (PV) cells
2. Automatic start and stop with solar radiation
3. Built-in maximum power point tracking (MPPT)
4. Easy installation and set-up for serial production
5. Compatible with all pump types
6. Good ROI (Return on Investment) against diesel powered pumping
7. Compact and uniform drive module design (IP20)
8. Dual supply capability with change over switch - solar and grid compatible
9. Sensorless vector control of induction motors and permanent magnet motors
10. Energy saving function and dry run self learning function 11 GPRS monitoring control via PC and Mobile
Electrical Specifications
| 220V | 380V |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 300~810VDC |
Normal working DC voltage | 260V-400V | 400V-650V |
Recommended input mppt voltage | 330V | 550V |
MPPT efficiency | >99% | |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz | |
Max efficiency of the machine | 99% | |
Ambient temperature range | -10 °C~50 °C, derating if the temperature is above 40 °C | |
Cooling method | Air cooling | |
Protection degree | IP20/IP21 | |
Altitude | Below 1000m; above 1% for every additional 100m. | |
Standard | CE/ROHS |
Accessories:
1. GPRS (support 2g/3g/4g internet)
2. LCD keypad
VFD500-PV 22KW 380V inverter picture:
Package:
When power is less than 45kw, we use carton package:
When power is more than 45kw, we use wood case package:
Mode Range
Drive model | Max DC input current (A) | Rated output current (A) | Applicable water pump (kW) |
VFD500M-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500M-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500M-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500M-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500M-40T00750-PV | 30.6 | 17 | 7.5 |
VFD500-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500-40T00750-PV | 30.6 | 17 | 7.5 |
VFD50040T01100-PV | 39.2 | 25 | 11 |
VFD500-40T01500-PV | 49.0 | 32 | 15 |
VFD500-40T01850-PV | 57 | 37 | 18.5 |
VFD500-40T02200-PV | 69 | 45 | 22 |
VFD500-40T03000-PV | 91 | 60 | 30 |
VFD500-40T03700-PV | 114 | 75 | 37 |
VFD500-40T04500-PV | 146 | 90 | 45 |
VFD500-40T05500-PV | 190 | 112 | 55 |
VFD500-40T07500-PV | 237 | 152 | 75 |
VFD500-40T09000-PV | 273 | 176 | 90 |
VFD500-40T11000-PV | 319 | 210 | 110 |
VFD500-40T13200-PV | 389 | 253 | 132 |
220V single phase or three phase level | |||
VFD500-20T00075-PV | 6.7 | 4.5 | 0.75 |
VFD500-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500-20T00220-PV | 14.1 | 10.6 | 2.2 |
VFD500-20T00400-PV | 22.6 | 17 | 4 |
VFD500M-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500M-20T00220-PV | 14.1 | 10.6 | 2.2 |
Techincal Parameters:
1. Wake up and sleep function parameters:
P47.05 | Light detection threshold | If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop | 0Hz |
P47.06 | Light detection time | See P47.05 for explanation. | 60s |
P47.07 | Light weak wake up time | After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. | 600s |
2. Dry runing protection function parameters:
P24.12 | Dry run/Unload protection option | 0: No offload detection is performed; 1: Enable dry run detection | 1 |
P24.13 | Dry run/Unload detection level | 0.0 to 200.0% The percentage of motor rated current. | 0.0% |
P24.14 | Dry run Unload detection time | 0.000s~60.000s | 30.000s |
P24.15 | Unload detection offset frequency | 0.00Hz~Fmax Detection frequency=Fmax-P24.15
| 5.00Hz |
P24.16 | Reset time of dry run protection | 0.0~6000.0 | 240.0s |
P23.21 | Dry run detection mode | 0000:Coast stop 1000:Fast stop 3000:Continue to run | 0000 |