VEIKONG VFD500-PV solar pump inverter Features:
1. Power from 220V (0.75 – 75KW) , 380V (0.75 – 160KW)
2. DC/AC Input Compatible, can support DC and AC Input at same time
3. Protection Functions: Over/Under voltage Over-current, Short Circuit, Phase Failure etc
4. Optimized MPPT Arithmetic Accuracy 99%
5. Multi-liquid-level Control, Dry run protection, Wake and Sleep function,,PID control
6. Auto-dormancy on weak light, auto-recovery working on strong light, no need for man-made operations
7. Auto switch over From Solar to Grid Supply with weak light
8. Support optional LCD display and GPRS module.
LCD and GPRS Pictures:
Electrical Specifications and Power degree
PV input | |
Maxiumum input DC voltage | 400V DC |
Recommended MPPT voltage range | 250~350V DC |
Recommended input Operation Voltage | 310V DC |
Grid or backup generator input | |
Input voltage | Single phase 220V(-15%~30%) |
Output Specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
380V Solar Pumping Inverter | |
Input Specification | |
PV input | |
Maxiumum input DC voltage | 800V DC |
Recommended MPPT voltage range | 450~650V DC |
Recommended input Operation voltage | 540V DC |
Grid or backup generator input | |
Input voltage | Three phase 380V(-15%~30%) |
Output specification | |
Rated ouput voltage | 3PH 380V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc. |
For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ
For 220V single phase motor connection
2: Single-phase asynchronous motor wiring method (with capacitor)
Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ