0.75-200kw MPPT 99% solar pump controller inverters for solar pv system irrigation
Product Details and Features:
1. Cover voltage levels 220V AC and 380V AC. Support single-phase 220V and three-phase 220V/380V pumps,the power from 0.4KW to 37KW.
2. Easy to use The inverters automatically start or sleep only after being connected to solar battery panels without any parameter setting.
3. Highly reliable for using multiple protective measures Including PV over-voltage protection,PV polarity reverse warning,and auto derating against over-temperture,which extend product life.
4. Use advanced MPPT algorithms,ensuring that the solar power tracking efficiency reaches 99%
5. Models of 2.2kW or lower can be configured with boost module,meeting low-voltage work requirements.This reduces the use of solar battery panels and therefore the cost.
6. it can implement auto switch between solar input and grid input by configuring the boost or auto switching cabinet(meeting lightning protection requirements),implementing 24-hour unattended work.
|
Electrical Specifications
PV input | |
Maxiumum input DC voltage | 400V DC |
Recommended MPPT voltage range | 250~350V DC |
Recommended input Operation Voltage | 310V DC |
Grid or backup generator input | |
Input voltage | Single phase 220V(-15%~30%) |
Output Specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
380V Solar Pumping Inverter | |
Input Specification | |
PV input | |
Maxiumum input DC voltage | 800V DC |
Recommended MPPT voltage range | 450~650V DC |
Recommended input Operation voltage | 540V DC |
Grid or backup generator input | |
Input voltage | Three phase 380V(-15%~30%) |
Output specification | |
Rated ouput voltage | 3PH 380V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc. |
1. GPRS (support 2g/3g/4g internet)
It supplies water volume monitoring and operation of inverter from anywhere at anytim
It’s convenient to visit real time and historical data via web or Android APP anytime and anywhere.
This easy-to-use platform makes monitoring of solar pump systems simple and convenient,
far reducing operate time and monitoring costs as well.
2. LCD keypad
Standard inverter are with LED keypad,LCD keypad is optional.
LCD keypad can monitor 4 parameters at the same time. LED keypad show one parameter only.
LCD keypad with detailed parameter explain,no need use user manual ,more user friendly.
LCD keypad with copy and update and download function.widely used for government projects and big farms.
VEIKONG SOLAR PUMP INVERTER PICTURE:
Mode Range
Drive model | Max DC input current (A) | Rated output current (A) | Applicable water pump (kW) |
VFD500M-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500M-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500M-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500M-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500M-40T00750-PV | 30.6 | 17 | 7.5 |
VFD500-40T00150-PV | 6.1 | 3.7 | 1.5 |
VFD500-40T00220-PV | 7.1 | 5 | 2.2 |
VFD500-40T00400-PV | 16.5 | 9.4 | 4 |
VFD500-40T00550-PV | 23.9 | 13 | 5.5 |
VFD500-40T00750-PV | 30.6 | 17 | 7.5 |
VFD50040T01100-PV | 39.2 | 25 | 11 |
VFD500-40T01500-PV | 49.0 | 32 | 15 |
VFD500-40T01850-PV | 57 | 37 | 18.5 |
VFD500-40T02200-PV | 69 | 45 | 22 |
VFD500-40T03000-PV | 91 | 60 | 30 |
VFD500-40T03700-PV | 114 | 75 | 37 |
VFD500-40T04500-PV | 146 | 90 | 45 |
VFD500-40T05500-PV | 190 | 112 | 55 |
VFD500-40T07500-PV | 237 | 152 | 75 |
VFD500-40T09000-PV | 273 | 176 | 90 |
VFD500-40T11000-PV | 319 | 210 | 110 |
VFD500-40T13200-PV | 389 | 253 | 132 |
220V single phase or three phase level | |||
VFD500-20T00075-PV | 6.7 | 4.5 | 0.75 |
VFD500-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500-20T00220-PV | 14.1 | 10.6 | 2.2 |
VFD500-20T00400-PV | 22.6 | 17 | 4 |
VFD500M-20T00150-PV | 9.9 | 7 | 1.5 |
VFD500M-20T00220-PV | 14.1 | 10.6 | 2.2 |
R&D test: test the hardware and software performance, to make the design more optimization, makes sure the products have excellent
performance before production;
Board test: test the performance of every board in our products, to reduce product defective rate;
IQC: take strict quality inspection for every income components, to ensure every income components are qualified.
Aging test: make the solar pump VFDs at run status, put them in the aging test house at 50°C for 48 hours, to remove every unqualified products.
Load test: the last and the most important test, add different load to the solar pump VFDs, test their input and output value, to check their
working performance. unqualified products will be removed from the team.
By applying such strict testing process, VEIKONG ensures every outgoing solar pump VFD has excellent quality.