Specifications
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
Western Union, T/T, L/C, PayPal
Supply Ability :
15000pcs per Month
Delivery Time :
3 days, depend on the order quantity
Packaging Details :
Carton and Wooden Box
Product Name :
220V Solar VFD
Size :
215*100*170mm
OEM :
Acceptable
Input mode :
Support AC and DC input
Warranty :
18 Months
Weight :
4kg
Description

220V Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

Product Features:

1.Cover voltage levels 220V AC and 380V AC.
Support single-phase 220V and three-phase 220V/380V pumps, the power from 0.4KW to 37KW.

2.Easy to use
The inverters automatically start or sleep only after being connected to solar battery panels without any parameter setting.

3.Highly reliable for using multiple protective measures
Including PV over-voltage protection, PV polarity reverse warning,and auto derating against over-temperture,which extend product life.

4.Use advanced MPPT algorithms, ensuring that the solar power tracking efficiency reaches 99%

5.Models of 2.2kW or lower can be configured with boost module, meeting low-voltage work requirements. This reduces the use of solar battery panels and therefore the cost.

6.VFD500-PV series can implement auto switch between solar input and grid input by configuring the boost or auto switching cabinet(meeting lightning protection requirements), implementing 24-hour unattended work.

7.Support the configuration of the GPRS module, which implements remote parameter viewing and control by using the mobile APP.

8.Support the cabinet solution for level IP54.


Electrical Specifications

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS


Model Range

Drive model

Max DC input current (A)

Rated output current (A)

Applicable water pump (kW)

VFD500M-40T00150-PV

6.1

3.7

1.5

VFD500M-40T00220-PV

7.1

5

2.2

VFD500M-40T00400-PV

16.5

9.4

4

VFD500M-40T00550-PV

23.9

13

5.5

VFD500M-40T00750-PV

30.6

17

7.5

VFD500-40T00150-PV

6.1

3.7

1.5

VFD500-40T00220-PV

7.1

5

2.2

VFD500-40T00400-PV

16.5

9.4

4

VFD500-40T00550-PV

23.9

13

5.5

VFD500-40T00750-PV

30.6

17

7.5

VFD50040T01100-PV

39.2

25

11

VFD500-40T01500-PV

49.0

32

15

VFD500-40T01850-PV

57

37

18.5

VFD500-40T02200-PV

69

45

22

VFD500-40T03000-PV

91

60

30

VFD500-40T03700-PV

114

75

37

VFD500-40T04500-PV

146

90

45

VFD500-40T05500-PV

190

112

55

VFD500-40T07500-PV

237

152

75

VFD500-40T09000-PV

273

176

90

VFD500-40T11000-PV

319

210

110

VFD500-40T13200-PV

389

253

132

220V single phase or three phase level

VFD500-20T00075-PV

6.7

4.5

0.75

VFD500-20T00150-PV

9.9

7

1.5

VFD500-20T00220-PV

14.1

10.6

2.2

VFD500-20T00400-PV

22.6

17

4

VFD500M-20T00150-PV

9.9

7

1.5

VFD500M-20T00220-PV

14.1

10.6

2.2


Product Application

220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

FAQ:

1. What should be noticed when installing inverter?
Put the product in a place where is well ventilate, cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.

2. Where is your factory located?
Our factory is located in Shenzhen, China, you are very welcome to visit our company.
Please feel free to contact us if you need information on road conditions or directions.

3. If pump is 60HZ frequency, how to set max frequency?

Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor, set P00.11=22; If your motor is single phase without capacitor, set P00.11=32
Send your message to this supplier
Send Now

220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

Ask Latest Price
Watch Video
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
video
220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation
220VAC Single Phase Solar Pump Inverter Solar Pump VFD For Agricultural Irrigation

Shenzhen Veikong Electric Co., Ltd.

Verified Supplier
4 Years
shenzhen
Since 2013
Business Type :
Manufacturer, Exporter
Total Annual :
15000000-20000000
Employee Number :
201~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement