Mppt efficiency 99% solar pump inverter 220v 0.75kw 1hp 1.5kw 2hp
Model Range
Drive Model | Related Voltage | Max DC input voltage (V) | Rated output current (A) | Applicable water pump (KW) | SIZE |
VFD500M-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500M-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500M-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500M-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500-20T00400-PV | 220V | 800 | 17 | 4 | SIZE A |
VFD500-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-40T00400-PV | 380V | 800 | 9.4 | 4 | SIZE A |
VFD500-40T00550-PV | 380V | 800 | 13 | 5.5 | SIZE B |
VFD500-40T00750-PV | 380V | 800 | 17 | 7.5 | SIZE B |
VFD500-40T01100-PV | 380V | 800 | 25 | 11 | SIZE C |
VFD500-40T01500-PV | 380V | 800 | 32 | 15 | SIZE C |
VFD500-40T01850-PV | 380V | 800 | 38 | 18.5 | SIZE D |
VFD500-40T02200-PV | 380V | 800 | 46 | 22 | SIZE D |
VFD500-40T03000-PV | 380V | 800 | 60 | 30 | SIZE E |
VFD500-40T03700-PV | 380V | 800 | 75 | 37 | SIZE E |
VFD500-40T04500-PV | 380V | 800 | 96 | 45 | SIZE F |
VFD500-40T05500-PV | 380V | 800 | 112 | 55 | SIZE F |
VFD500-40T07500-PV | 380V | 800 | 150 | 75 | SIZE G |
VFD500-40T09000-PV | 380V | 800 | 176 | 90 | SIZE G |
VFD500-40T11000-PV | 380V | 800 | 210 | 110 | SIZE H |
VFD500-40T13200-PV | 380V | 800 | 253 | 132 | SIZE I |
VFD500-40T16000-PV | 380V | 800 | 304 | 160 | SIZE I |
VFD500-40T18500-PV | 380V | 800 | 340 | 185 | SIZE J |
VFD500-40T20000-PV | 380V | 800 | 377 | 200 | SIZE J |
Key Advantages:
1, The power range is from 220V 0.75kw to75kw, and 380v 0.75kw to 160kw
1, MPPT control mode, adjust the output frequency to the appropriate frequency in real-time.
2,,Adjust water outflow of pumps quickly on basis of sunlight intensity change.
3,With functions of light weak protection, dry run and low voltage,full water warning, overvoltage and overtemperature protection.
4, New keyboard design, support optional LCD keypad, simple appearance, and easy operation.
5,Automatic running without any commisioning in keypad control and GPRS monitoring option(as option).
6,Support PMSM pump
Techincal Parameters:
1. Wake up and sleep function parameters:
P47.05 | Light detection threshold | If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop | 0Hz |
P47.06 | Light detection time | See P47.05 for explanation. | 60s |
P47.07 | Light weak wake up time | After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. | 600s |
2. Dry runing protection function parameters:
P24.12 | Dry run/Unload protection option | 0: No offload detection is performed; 1: Enable dry run detection | 1 |
P24.13 | Dry run/Unload detection level | 0.0 to 200.0% The percentage of motor rated current. | 0.0% |
P24.14 | Dry run Unload detection time | 0.000s~60.000s | 30.000s |
P24.15 | Unload detection offset frequency | 0.00Hz~Fmax Detection frequency=Fmax-P24.15
| 5.00Hz |
P24.16 | Reset time of dry run protection | 0.0~6000.0 | 240.0s |
P23.21 | Dry run detection mode | 0000:Coast stop 1000:Fast stop 3000:Continue to run | 0000 |
3. Water full protection function parameters:
P47.18 | Full water level detection channel | 0:ineffective 1:AI1 2:AI2 3:AI3 4:AI4 Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same. | 0 |
P47.19 | Full water level detection value | 0.0~100.0%
| 0.0% |
P47.20 | Full water level detection time | 0.0~3000.0s When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.
| 10.0s |
P47.21 | Full water recovery time | 0.0~3000.0s When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay | 10.0s |
Support optional LCD keypad
Support optional GPRS Module