5.5kw 7.5kw 11kw 15kw Online Intelligent Ac Motor Soft Starter
Product Feature
Reliable quality
The computer simulation design.
SMT production process.
Good EMC performance.
The machine before delivery on the high temperature aging, vibration test.
Perfect and reliable system protection function
Protection of no voltage, less voltage and over voltage.
Protection of overheating and starting time too long.
Protection of Input phase lost, output phase lost and 3phase unbalance.
Protection of starting over current, running overload, and load short circuit protection.
Maintenance function
Fault self-diagnosis(Short circuit, over voltage, less voltage, one phase grounded, motoroverload, one phase lost, motor blocked, and intelligent software can inspect drag system working state).
Combination of modular design, according to the fault display content, quick troubleshooting.
Technical Specification
Item | Description | ||
Input Power Supply | Input Voltage | Three-phase 380V/480V/660 AC | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. | ||
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | (1) Soft stop. (2) Free stop. | ||
Protective Function | (1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. o | ||
Temperature | -20 +45 C | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Fans cooling. |
Product Application
FAQ
1. Do you accept customized order?
Yes, we do.
2. Can I have a sample order?
Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
3. How to ship?
Please inform us of your requirements, whether it is by sea, air or express, it is all right for us. We have very professional logistics channels to provide the best transportation cost, service and guarantee.