18.5kw 25hp AC drive vfd variable speed drive single phase three phase
Features
It adopts DSP as the core control unit to realize high - speed high - performance control.
◆ Speed control: no PG vector control, PG vector control, V/F control.
◆ The low frequency 0.25Hz and 180% torque output are realized under the non - inductive vector.
◆ The simple PLC function can achieve up to 16 speed control.
◆ The multi-lingual humanized display menu, highlight OLED and display 3 sets of state parameters.
◆ The "one key flying shuttle" keyboard can fly freely.
◆ Optimized air duct design and advanced thermal management technology.
◆ The design of reliable insulation structure ensures the safety of the inverter.
◆ The fully isolated RS485 communication module can be selected to communicate with the upper computer.
◆ We will strengthen the coating and adapt to all kinds of harsh environment.
◆ Relying on EMC design standard and unique software algorithm, the inverter can minimize the pollution of power supply.
VFD500 parameter distribution list
Classification | Parameter group | Page |
Common parameters | 00:Basic function | Page 30 |
01:Frequency source selection | Page 32 | |
02:Start and stop | Page 37 | |
03:Ramp and S curve | Page 39 | |
04: Analog and pulse input | Page 41 | |
05:Analog and pulse output | Page 45 | |
06: Multi-function Digital input (DI) | Page 46 | |
07: Multi-function Digital output(DO) | Page 49 | |
08:Digital Output setting | Page 51 | |
Motor control | 10:Encoder type | Page 53 |
11:Motor1 parmeter | Page 54 | |
12:Motor1 VFcontrol parameter | Page 56 | |
13:Motor1 Vector controlparameter | Page 58 | |
14:Torque control | Page 59 | |
16:Energy saving control | Page 61 | |
Display and protection | 20:User-defined parameters | Page 62 |
21:Keypad and display | Page 63 | |
22:AC Drive configuration | Page 65 | |
23:Drive protection function setting | Page 67 | |
24:Motor protection parameter | Page 70 | |
25:Fault tracking parameter | Page 72 | |
26:Fault recording parameter | Page 72 | |
27:Monitoring parameter | Page 74 | |
Communication | 30:Modbus communication | Page 75 |
Application | 40:Process PID Function | Page 77 |
41:Sleep function | Page 81 | |
42:Simple PLC | Page 82 | |
43:Programmable delay unit | Page 84 | |
44:Comparator and logic unit/controller | Page 86 | |
45:Multifunction counter | Page 90 | |
Motor 2 | 60:Motor2 basic parameter | Page 91 |
61:Motor2 parameter | Page 91 | |
62:Motor2 VF control parameter | Page 92 | |
63:Motor2 vector control parameter | Page 92 |
Techincal Parameters:
Item | Specifiation | |
Input | Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Output | Output Voltage | 3phase:0~input voltage |
Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current | |
Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) | |
Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) | |
frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
VEIKONG VFD APPLICATION: