Inverter with LCD display 220v 380v 4kw 5.5kw 7.5kw for CNC application
VFD500 features and technical data sheet:
Item | Specifiation | |
Input | Inuput Voltage | 1phase/3phase 220V:200V~240V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Output | Output Voltage | 3phase:0~input voltage |
Overload capacity | General purpose application:60S for 150% of the rated current | |
Control | Control mode | V/f control |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range | 1:100 (V/f) | |
Speed control accuracy | ±0.5% (V/f) | |
Speed response | 5Hz(V/f) | |
frequency range | 0.00~600.00Hz(V/f) | |
Input frequency resolution | Digital setting: 0.01 Hz | |
Startup torque | 150%/0.5Hz(V/f) | |
Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% | |
V/f curve | V / f curve type: straight line, multipoint, power function, V / f separation; | |
Frequency giving ramp | Support linear and S curve acceleration and deceleration; | |
DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault; | |
Carrier frequency | 1kHz~12kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Maincontrol function | Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN | |
Function | Keypad | LED Digital keyboard and LCD keypad(option) |
Communication | Standard: | |
PG card | Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card | |
Input terminal | Standard: | |
Output terminal | standard: | |
Protection | Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function | |
Environment | Installation location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m | |
Ambient temperature | -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°C ~ +60°C | |
Others | Installation | Wall-mounted, floor-controlled cabinet, transmural |
Protection level | IP20 | |
cooling method | Forced air cooling | |
EMC | CE ROHS | Internal EMC filter |
Replace famous brands vfd in general application.
;
Veikong application picture: