Specifications
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability :
15000pcs per Month
Delivery Time :
3 days, depend on the order quantity
Packaging Details :
Carton and Wooden Box
Product Name :
5HP 10HP 15HP 20HP 30HP Three Phase Solar Pump Inverter
Output Frequency :
50Hz/60Hz
Keyboard :
LED/LCD
Warranty :
18 Months
Power Range :
0.75-250KW
Colar :
Blue
OEM :
Support
STO funciton :
Support
Carrier frequency :
1kHz~12kHz
PG card for options :
Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary Card , frequency division signal pg card
Keypad :
LED, LCD and shuttle display for options
Description

5HP 10HP 15HP 20HP 30HP 3 Phase Solar Pump Inverter With LCD Keyboard

5HP 10HP 15HP 20HP 30HP Three Phase Solar Pump Inverter With LCD Keyboard

Product Feature

1, Support 220V and 380V, single phase and three phase solar water pump inverter, power from 0.75kW to 160KW

2, No need to set any parameters, and the inverter can be automatically started after power-on

3, It has protection functions such as PV over-voltage protection, PV polarity reverse connection alarm, over-temperature automatic derating, etc., which can effectively extend the life of the product

4, Supports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP

5, It can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work

3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions

Product Model Range

Drive model Max DC input current (A) Rated output current (A) Applicable water pump (kW)
VFD500M-40T00150-PV 6.1 3.7 1.5
VFD500M-40T00220-PV 7.1 5 2.2
VFD500M-40T00400-PV 16.5 9.4 4
VFD500M-40T00550-PV 23.9 13 5.5
VFD500M-40T00750-PV 30.6 17 7.5
VFD500-40T00150-PV 6.1 3.7 1.5
VFD500-40T00220-PV 7.1 5 2.2
VFD500-40T00400-PV 16.5 9.4 4
VFD500-40T00550-PV 23.9 13 5.5
VFD500-40T00750-PV 30.6 17 7.5
VFD50040T01100-PV 39.2 25 11
VFD500-40T01500-PV 49.0 32 15
VFD500-40T01850-PV 57 37 18.5
VFD500-40T02200-PV 69 45 22
VFD500-40T03000-PV 91 60 30
VFD500-40T03700-PV 114 75 37
VFD500-40T04500-PV 146 90 45
VFD500-40T05500-PV 190 112 55
VFD500-40T07500-PV 237 152 75
VFD500-40T09000-PV 273 176 90
VFD500-40T11000-PV 319 210 110
VFD500-40T13200-PV 389 253 132
220V single phase or three phase level
VFD500-20T00075-PV 6.7 4.5 0.75
VFD500-20T00150-PV 9.9 7 1.5
VFD500-20T00220-PV 14.1 10.6 2.2
VFD500-20T00400-PV 22.6 17 4
VFD500M-20T00150-PV 9.9 7 1.5
VFD500M-20T00220-PV 14.1 10.6 2.2

Product Application

3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions

3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions

FAQ

1. How to achieve Automatic start after stop?

If it is controlled by keyboard no need to set any parameter. If you want to control by external switch

As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com and DI1, When the switch is closed, the drive run, when the switch is open, the drive stop

2. How to use a float in the water tank to stop the pump if the tank is full?

If your float signal is digital signal Use float switch to short DI 1 and com and P00.06=1

3. Use level probe in the well for protection against dry running

Set P24.13=30%-40% and P24.14 P24.16 and P23.21

If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and P41.03-P41.06

4. How to set minimum frequency ( for example) 30hz and maximum 50HZ?

Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07

5. If pump is 60HZ frequency, how to set max frequency?

Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.

Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor, set P00.11=22; If your motor is single phase without capacitor, set P00.11=32

Send your message to this supplier
Send Now

3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions

Ask Latest Price
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions
3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions
3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions
3 Phase Solar Pump Inverter for Single and Three Phase Pumps with Protection Functions

Shenzhen Veikong Electric Co., Ltd.

Verified Supplier
4 Years
shenzhen
Since 2013
Business Type :
Manufacturer, Exporter
Total Annual :
15000000-20000000
Employee Number :
201~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement