Specifications
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Payment Terms :
Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability :
15000pcs per Month
Delivery Time :
3 days, depend on the order quantity
Packaging Details :
Carton and Wooden Box
Product Name :
IP20 380V 5.5KW Solar Pump Inverter
Current :
13A
Keypad :
LED/LCD
Working Principle :
AC-DC-AC
Frequency :
50HZ/60HZ
Colar :
Blue
Description

IP20 380V 5.5KW Solar Pump Inverter With 99% MPPT Tracking and GPRS Function

Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)

1. Operates without grid directly from photovoltaic (PV) cells

2. Automatic start and stop with solar radiation

3. Built-in maximum power point tracking (MPPT)

4. Easy installation and set-up for serial production

5. Compatible with all pump types

6. Good ROI (Return on Investment) against diesel powered pumping

7. Compact and uniform drive module design (IP20)

8. Dual supply capability with change over switch - solar and grid compatible

9. Sensorless vector control of induction motors and permanent magnet motors

10. Energy saving function and dry run self learning function 11 GPRS monitoring control via PC and Mobile

Solar Pump Inverter Special Parameters

Function code Name Description Default Property
47 Group solar pumping special group
P00.03 RESET

0:NO ACTION

11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

12:Restore default to factory parameter 13:Clear tripping record

0
P00.06 Source of the Operation Command

0:keypad

1:terminal

2:communication

Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

0
P00.07 Numeric frequency setting 00.00Hz~maximum frequency 50.00Hz
P00.11 Application Macro

01:Output three phase 50HZ

02:Output three phase 60hz

21:Output single phase with capacitor 50hz

22:Output single phase with capacitor 60hz

31:Output single phase without capacitor 50hz

32:Output single phase without capacitor 60hz

00
P01.06 Maximum frequency 10.00~600.00Hz 50.00Hz
P01.08 Upper limit frequency Lower limit frequency-maximum frequency 50.00Hz
P07.03 Relay 1 Output terminal function group(T1A T1B T1C)

0:No function

1:READY

2:RUN

3:Error1(stop fault)

4:Error2(same as Error1 except undervoltage)

5:Warning output(fault but in running)

3
P11.01 AC asynchronous motor TYPE

0:Three phase AC asynchronous motor

1:Single phase AC asynchronous motor without starting capacitor

0
P11.02 Motor rated power

0.1kW~710.0kW

Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

Depend
P11.03 Motor rated voltage 10V~2000V Depend
P11.04 Motor rated current

P11.02<30kW:0.01A

P11.02>=30kW:0.1A

Depend
P11.05 Motor rated frequency 1.00Hz~600.00Hz 50.00Hz
P11.06 Motor rated RPM 1~60000rpm Depend
P21.00 Monitoring display

0:Standard mode (display frequency only)

1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

0
P23.15 Output phase loss function 0.0-30%, 0% means output phase detections shielded 30%
r27.15 Accumulative running time Unit:hour
P47.00 Solar pump Mppt function enable

0: invalid

The parameters behind the 47 group cannot be changed!

1: Enable, to enable the special mppt function of the PV pump inverter

1
P47.01

Solar pump control mode

Units digit’s: Startup mode

0: Manual start, the start mode is determined by P00.06;

1: automatic start,

When P00.06 change, the association changes here.

P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start

P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start

Ten digit’s: MPPT function

0: MPPT is disabled; CVT control is used (voltage is given as P47.04).

1: Enable MPPT.

11
P47.03 Automatic start timing In auto start mode, set the time from power on to start. It is also waiting time to start 600
P47.04 MPPT starting voltage

Set the starting voltage of the MPPT algorithm.

When the MPPT function is disabled, this value is the reference voltage.

305V(530V)
P47.05 Light detection threshold If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop 0Hz
P47.06 Light detection time See P47.05 for explanation. 60s
P47.07 Light weak wake up time After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. 600s
P47.08 MPPT tracking step length The amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point. 2V
P47.09 Regulator proportional gain 0.001~1.00 It is for immediate response speed, it is not recommended to change 0.05
P47.10 Regulator integral gain 0.001~0.100 tracking response.it is not recommended to change 0.05
P47.28 Starting coefficient 0.000~1.000 0.850
P47.30 Fast speed function

Unit digit:fast starting

0:Disable 1:Enable

Ten digit:Fast mppt tracking

0:Disable 1:Enable

11

13A 5.5KW MPPT VFD Solar Pump Inverter GPRS IP20 380V LED LCD


Product Application

13A 5.5KW MPPT VFD Solar Pump Inverter GPRS IP20 380V LED LCD

13A 5.5KW MPPT VFD Solar Pump Inverter GPRS IP20 380V LED LCD

FAQ

1. Does the product need to set a lot of parameters?

No, it doesn't. The inverter has a self-adaptive and self-learning function. It is automatic start and stop, you can press Run key to start, or you just wait for P47.03=600S(Default) then it will automatically start

2. Could it replace my previous PV pumping inverter?

Yes, of course. Selecting inverter model according to the rated voltage, current and power of the water pump. A bit more is better. Then take off the old one and put ours on, the system will work.

3. How to design solar PV water pump system?

Key point: the rated VOC and VMP and power of the PV Array need to match the input range of the inverter. If needed, we will provide technical support online.

4. How to make the water pump system work without sunshine?

Usually, solar PV water pump system can meet the needs of pumping water.

If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design

Send your message to this supplier
Send Now

13A 5.5KW MPPT VFD Solar Pump Inverter GPRS IP20 380V LED LCD

Ask Latest Price
Brand Name :
VEIKONG
Model Number :
VFD500-PV
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
13A 5.5KW MPPT VFD Solar Pump Inverter GPRS IP20 380V LED LCD

Shenzhen Veikong Electric Co., Ltd.

Verified Supplier
4 Years
shenzhen
Since 2013
Business Type :
Manufacturer, Exporter
Total Annual :
15000000-20000000
Employee Number :
201~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement