Specifications
Brand Name :
Kinda
Model Number :
KD386
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
Adequate inventory
Delivery Time :
5~8 Day
design :
Modular design, compact structure, easy maintenance and enhanced product interchangeability
PCB protection :
Spray three anti-paint to protect the circuit board intelligently and efficiently
run :
Smooth main/slave switching, no change in water pressure
start up :
Simple parameter setting, one-button start automatic addition and subtraction pump control
control :
Main/slave control energy saving
installation :
Simple wiring installation
Description

Water Pump Single Phase Variable Frequency Drive 1AC 220V 0.75KW 1.5KW 2.2KW

When the pressure of the pressure transmitter is the largest, the frequency of the inverter is the lowest, and the speed of the pump motor is the lowest. When the pressure of the pressure transmitter is the smallest, the frequency of the inverter is the highest, and the speed of the pump motor is the highest. The frequency of the inverter changes with the change of water consumption. After the PID adjustment parameters are modified, the pipeline pressure is always kept constant; even if the water consumption is a variable, the final pressure is constant.

Water Pump 220V Single Phase Frequency Inverter Energy Saving Simple Wiring Installation

Function code Default value Set value Description
F1-11 1 I# inverter 1 1# inverter (master), it must connect the pressure sensor.
2# inverter 2 2# inverter (slave / standby master), connect the pressure senor.
3# inverter 3 3# and 4# inverters (slave).
4# inverter 4 Warning: the address of each inverter cannot be the same, otherwise, the system will work abnormally.
F0-00 1 2 Multiple pumps system
F0-01 0.4MPa Customer set 1. Please set it correctly based on requested pressure, the unit is MPa, 1MPa=10bar.
2. Most of the family used systems, the pressure is 0.3~0.4MPa (3~4bar)
F0-02 80% Customer set Wake up pressure; it is the percentage of F0-01.
F0-03 0 0 It must be set as “0” while use 0~10V remote pressure gauge.
1 It must be set as “1” while use 4~20mA pressure transducer.
F0-04 1.6MPa 1.6MPa 1. To set the maximum measure range of pressure transducer.
2. It must be set correctly, otherwise it may cause pressure is inaccurate.
F0-25 300Min Customer set To set the running time as master pump, when time arrive, it switches to next pump as master.
When set F0-25=0, this pump will only work as slave pump.

Water Pump 220V Single Phase Frequency Inverter Energy Saving Simple Wiring Installation

Send your message to this supplier
Send Now

Water Pump 220V Single Phase Frequency Inverter Energy Saving Simple Wiring Installation

Ask Latest Price
Brand Name :
Kinda
Model Number :
KD386
Place of Origin :
China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
T/T
Contact Supplier
Water Pump 220V Single Phase Frequency Inverter Energy Saving Simple Wiring Installation
Water Pump 220V Single Phase Frequency Inverter Energy Saving Simple Wiring Installation

Shenzhen Kinda Technology Co., Ltd

Active Member
7 Years
guangdong, shenzhen
Since 2012
Business Type :
Manufacturer
Total Annual :
12000000.00-15000000.00
Employee Number :
300~500
Certification Level :
Active Member
Contact Supplier
Submit Requirement