50g 11ms , 150 6ms Small Shock Tester Comply with UN38.3 Battery Testing Standard
Shock Test System
The HSKT series shock test system is mainly applicable to shock resistance tests in such fields as electronic products, battery products, aerospace, ship, military industry, automotive parts and transportation. Shock tests are in form of half sine wave, saw tooth wave or trapezoidal wave. Shock tests can be carried out by selecting different waveform generators.
The equipment conforms to such testing specifications as GB/T2423-2008, GJB150, GJB360, GJB548, UN38.3, IEC-62281, GJB1217, MIL-STD-202F, IEC-68-2-27, MIL-STD-810F, MIL-STD-883E, etc.
Parameters:
Technical Specifications
Model | HSKT10 | HSKT30 |
Table size (mm) | 200x250 | 300x300 |
Shock pulse | Half sine |
Maximum Specimen Weight(Kg) | 10 | 30 |
Acceleration Range(G) | 20 ~ 2000 | 20 ~ 1500 |
Pulse Duration (ms) | 0.2~18 | 0.5~30 |
Machine Dimension(mm) | 660x700x2380 | 720x680x1890 |
Utility Requirements | AC220V 50Hz 5A,Air pressure: more than 0.5Mpa |
Machine Weight(Kg) | 820 | 650 |
Features
- Customized table mounting patterns available
- Dual Mass Shock Amplifiers to generate extremely high acceleration levels (20,000g+)
- Additional Shock Pulse Programmers
- Test Partner Data Acquisition and instrumentation for data collection and analysis

Warranty:
One year limited warranty with lifetime support; extended warranty available upon request at additional cost.
After-sale service:
On site installation and trainning are avaiable at extra cost.
Technical support
Certificate: China official third-party calibration report / CE Certification
Customer Service
Service timeliness
When a fault report is received from customer〈including telephone, fax and email〉:
LABTONE will respond within 4-8 hours (working time), provide solutions and eliminate faults within 12-24 hours. After the equipment's guarantee period ended, supplier still has obligation to provide users with technical supports and after-sales services.
Presales:
- Technical consultation: test method, laboratory planning and suggestion.
- Equipment selection: selection scheme, FAQ.
- Product testing scheme.
In-Sales:
- Customer communication and progress report.
- Guidance for pre-installation preparation, equipment commissioning and test run
- Calibration (when Third Party’s verification is required)
After-Sales:
- Technical training: operation of equipment, daily maintenance, common fault diagnosis and troubleshooting.
- Scheduled on-site service: Detection of problem as soon as possible in order to eliminate equipment and anthropogenic hazards. This is to ensure long term and stable equipment operation as well as delivery of latest technical information.
- Technical support: special paid services are provided according to customer’s needs.
Production: