Specifications
Brand Name :
VICTOR
Model Number :
VICTOR 02S
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
USD115/pc
Payment Terms :
T/T, Western Union, L/C, Paypal
Supply Ability :
3000pcs available
Delivery Time :
5 to 30 days
Packaging Details :
10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton
Color :
Blue or Orange and Black
Size :
180*90*47mm
Product Name :
Temperature Source
Model No. :
VICTOR 02S
Material :
Plastic, metal, silica gel
Packing Details :
10pcs/Carton; Carton Size: 39.5*38.5*26cm
Accuracy :
0.05% accuracy
Weight :
Approx. 900 g (including batteries)
Power supply :
2*1.5V AA Alkaline battery
Description

VICTOR 02SThermocouple Calibrator Imput And Output Source 8 Types Of Thermocouple Measurement (R/S/K/E/J/T/B/N)

VC02S TEMPERATURE CALIBRATOR

Basic characteristics of the product

  • Input measurement characteristics
  • Basic functions

DC voltage DCV, resistance OHM, thermocouple TC, thermal resistance RTD, on/off

  • The maximum measurement accuracy is 0.05% and the measurement display is 5 digits.
  • Measurement rate: 2-3 times/sec.
  • 2W / 3W / 4W measurements are available for OHM and RTD.
  • The measured temperature value and the corresponding temperature signal are displayed on the same screen.
  • Analog output characteristics
  • Basic functions

DC voltage DCV, resistance OHM, thermocouple TC, thermal resistance RTD

  • The maximum output accuracy is 0.05% and the output display is 5 digits.
  • Output settings can be manually increased or decreased by position.
  • H/L settings are available for OHM excitation current.
  • The output temperature value and the corresponding temperature signal are displayed on the same screen.
  • It has a built-in high-precision temperature sensor for high-precision cold-end compensation.

Thermocouple cold-end compensation can be set, including manual compensation, automatic compensation, compensation access disconnection, etc.

  • It has maintenance setup functions, including

Auto power-off, backlight, flashlight, buzzer, etc.

  • Others
  • The segment code is displayed on an LCD with a white backlight.
  • It has a LED flashlight for lighting.
  • It is powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery detection is available.
  • It is small, firm, reliable, suitable for field use, and cheap.
  • User-optional large-suction magnetic sling is provided.

II. Basic function and performance of the product (technical index)

RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator

Analog output function [Used within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+% reading)]

Output function Range Output range Resolution Accuracy Remarks

DC voltage

DCV

100mV -10.000mV~110.00mV 0.01mV 0.05%+0.03mV Maximum output current: 0.5mA
1V -0.1000V~1.1000V 0.0001V 0.05%+0.3mV Maximum output current 2mA

Ohm

OHM

400Ω 0~400.0Ω 0.1Ω 0.05%+0.2Ω

The excitation current is ±0.1~±5mA

Maximum output voltage 2V

When the excitation current is ±0.1~0.5mA, additional error of 0.1Ω is added

The accuracy does not include lead resistance

4KΩ 0~4.000KΩ 0.05%+2Ω

Thermocouple

TC

R 0°C~1767°C 1°C

0~100℃

10~1767℃

0~100℃

100~1767℃

1.5℃

1.2℃

1.5℃

1.2℃

Use ITS-90 temperature scale

The accuracy does not include the error of cold junction compensation

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

R: Platinum Rhodium 13- Platinum

S: Platinum Rhodium 10- Platinum

K: Nickel chromium - nickel silicon

E: Nickel chromium - copper nickel (constantan)

J: Iron - copper nickel (constantan)

T: Copper - nickel (constantan)

N: Nickel chromium silicon nickel silicon

B: Platinum Rhodium 30 - Platinum

A: Tungsten rhenium 5- Tungsten rhenium 20

C: Tungsten rhenium 5- Tungsten rhenium 26

D: Tungsten rhenium 3- Tungsten rhenium 25

S 0°C~1767°C
K -200.0°C~1372.0°C 0.1°C

-200.0~-100.0℃

-100.0~400.0℃

400.0~1200.0℃

1200.0~1372.0℃

0.6℃

0.5℃

0.7℃

0.9℃

E -200.0°C~1000.0°C

-200.0~-100.0℃

-100.0~600.0℃

600.0~1000.0℃

0.6℃

0.5℃

0.4℃

J -200.0°C~1200.0°C

-200.0~-100.0℃

-100.0~800.0℃

800.0~1200.0℃

0.6℃

0.5℃

0.7℃

T -250.0°C~400.0°C -250.0~400.0℃ 0.6℃
N -200.0°C~1300.0°C

-200.0~-100.0℃

-100.0~900.0℃

900.0~1300.0℃

1.0℃

0.7℃

0.8℃

B 600°C~1820°C 1°C

600~800℃

800~1820℃

1.5℃

1.1℃

A 0°C~2500°C 1°C

0~1600℃

1600~2000℃

2000~2500℃

2.0℃

2.2℃

2.4℃

C 0°C~2310°C 1°C

0~1600℃

1600~2000℃

2000~2310℃

2.0℃

2.2℃

2.4℃

D 0°C~2310°C 1°C

0~100℃

100~270℃

270~1200℃

270~2310℃

2.6℃

2.4℃

2.2℃

2.4℃

Thermal resistance

RTD

Pt100

385

-200.0°C~800.0°C 0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.3℃

0.5℃

0.8℃

Use Pt (385) temperature scale

The excitation current is ±0.1~±5mA

Maximum output voltage 2V

When the excitation current is ±0.1~0.5mA, additional error of 0.1Ω is added

The accuracy does not include lead resistance

The accuracy does not include the influence of thermoelectric potential

Support pulse transmitters and PLCs with pulse times as short as 10ms

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.2℃

0.5℃

0.7℃

Cu50 -50.0°C~150.0°C 0.6℃

Other characteristics:

  • Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
  • Load characteristics: capacitive load ≥0.01uF (DCV/OHM/TC/RTD/FREQ); Inductive load ≥ 0.01uF 100uH (DCA)

Output load affects DCmV (0.001% full scale + 1nV)/mA; DCV (0.001% full scale + 1nV)/mA

  • The temperature range of internal temperature compensated sensor RJC is -10 to 50°C. The temperature measurement accuracy at 18 to 28°C is ±0.5°C, and the temperature measurement accuracy at other temperature is ±1°C. Cold end compensation time is 10S/ times.
  • Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)

Input measurement function [Used within one year after calibration, 23℃±5℃, 20-70% RH, accuracy =+/-(% set point + reading %)]

Measurement function Range Measurement range Resolution Accuracy Remarks

DC voltage

DCV

100mV -110.00mV~110.00mV 0.01mV 0.05%+0.03mV Input resistance: approximately 1MΩ
1V -1.1000V~1.1000V 0.0001V 0.05%+0.3mV
35V -35.000V~35.000V 0.001V 0.02%+2mV

Resistance

OHM

500Ω 0~550.00Ω 0.01Ω 0.05%+0.2Ω

2W/3W/4W measurement

50 Ω approximately 1mA excitation

5KΩ approximately 0.1mA excitation

Open circuit voltage: approximately 2.5V

The accuracy does not include lead resistance

5KΩ 0~5.5000KΩ 0.0001KΩ 0.05%+2Ω

Thermocouple

TC

R 0°C~1767°C 1°C

0~500℃

500~1767℃

2.5℃

2℃

Use ITS-90 temperature scale

The accuracy does not include the error of cold junction compensation

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

R: Platinum Rhodium 13- Platinum

S: Platinum Rhodium 10- Platinum

K: Nickel chromium - nickel silicon

E: Nickel chromium - copper nickel (constantan)

J: Iron - copper nickel (constantan)

T: Copper - nickel (constantan)

N: Nickel chromium silicon nickel silicon

B: Platinum Rhodium 30 - Platinum

A: Tungsten rhenium 5- Tungsten rhenium 20

C: Tungsten rhenium 5- Tungsten rhenium 26

D: Tungsten rhenium 3- Tungsten rhenium 25

S 0°C~1767°C
K -100.0°~1372.0°C 0.1°C

-100.0~0.0℃

0.0~1372.0℃

1.2℃

0.8℃

E -50.0°C~1000.0°C

-50.0℃~0.0℃

0.0~1000.0℃

0.9℃

1.5℃

J -60.0°C~1200.0°C

-60.0~0.0℃

0.0~1200.0℃

1.0℃

0.7℃

T -100.0°C~400.0°C

-100.0~0.0℃

0.0~400.0℃

1.0℃

0.7℃

N -200.0°~1300.0°C

-200.0~0.0℃

0.0~1300.0℃

1.5℃

0.9℃

B 600°C~1820°C 1°C

600~800℃

800~1000℃

1000~1820℃

2.2℃

1.8℃

1.4℃

A 0°C~2500°C 1°C

0~1600℃

1600~2000℃

2000~2500℃

2.0℃

2.2℃

2.4℃

C 0°C~2310°C 1°C

0~1600℃

1600~2000℃

2000~2310℃

2.0℃

2.2℃

2.4℃

D 0°C~2310°C 1°C

0~100℃

100~270℃

270~1200℃

270~2310℃

2.6℃

2.4℃

2.2℃

2.4℃

Thermal resistance

RTD

(4W)

Pt100

385

-200.0°C~800.0°C 0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.5℃

0.7℃

0.8℃

Use Pt (385) temperature scale

2W/3W/4W measurement

50 Ω approximately 1mA excitation

5KΩ approximately 0.1mA excitation

Open circuit voltage: approximately 2.5V

The accuracy does not include the error caused by the mismatch of the 2 W/3 W measurement lead resistance

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.3℃

0.5℃

0.7℃

Cu50 -50.0°C~150.0°C -50.0~150.0℃ 0.7℃
On/off detection 500Ω ≤50Ω sounding 0.01Ω

Approximately 1mA excitation

RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator

RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibratorRTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator

Send your message to this supplier
Send Now

RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator

Ask Latest Price
Brand Name :
VICTOR
Model Number :
VICTOR 02S
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
USD115/pc
Contact Supplier
RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator
RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature Calibrator Tc and RTD calibrator

XI'AN BEICHENG ELECTRONICS CO.,LTD

Site Member
5 Years
Since 1980
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
200~500
Certification Level :
Site Member
Contact Supplier