Specifications
Brand Name :
VICTOR
Model Number :
VICTOR 606D
Certification :
CE
Place of Origin :
CHINA
MOQ :
300
Payment Terms :
T/T, Western Union, L/C,Paypal
Supply Ability :
10000 pc available
Delivery Time :
5-30 days
Packaging Details :
Color box ,40pcs/Carton ,23.6KG/Carton
Price :
100pcs: USD13/pc; 100pcs to 500pcs: USD12.5/pc; 500pcs to 1000pcs: USD12/pc; Above 3000pcs: USD11.5/pc
Color :
Black and orange
Weight :
Approx 176g
Packing :
Color box
Hold :
Data hold
Product Size :
174*66*30mm
Operation way :
Auto range
Clamp size :
32 mm
Battery :
1.5V*2
Description

10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp

VICTOR 606D Multimeter 4000 Counts Pocket Clamp Digital Multimeter 3 3/4 Large LCD Display 600V 600A 40MΩ 10kHz 10mF with temp.

1. SAFETY OPERATION RULE

The meter’s design is in accordance with the CE certification, meets the standard ofIEC61010-1, IEC61010-2-032, IEC 61010-031, IEC61010 CAT.III 600V and Grade II pollution. Read the following before operation.

1.1 Use the meter in accordance with the standards or requirements of this manual, otherwise the protection function provided by the instrument may be damaged or declined.

1.2 To avoid electric shock, be careful when measuring the voltage higher than 60V DC RMS, 30V AC

1.3 Do not input the voltage over the limit value between the terminals or between each terminal and ground.

1.4 Check whether the meter works properly by measuring the voltage or current which were known beforehand. Do not use any more if it is improper or damaged.

1.5 Please check the meter before operation, if the shell is cracked or the plastic parts are damaged, please stop using it again.

1.6 Before operation, please check the test leads, if there are cracks or damage on it, please replace the test leads with same model or the same electrical specifications.

1.7 Do not measure over range of the meter, accessories as probe, and CAT Level.

1.8 When inserting the test leads in the input jack, do not measure the current

1.9 Do not operate with the meter independently

1.10 Please comply with local and national safety regulations. Wear personal protective equipment (such as approved rubber gloves, face masks, and flame-retardant clothing etc.) to prevent the injury from electric shock and arc when charged conductors are exposed.

1.11 When the low battery symbol appears, please replace the battery in time to avoid the wrong values

1.12 Do not use the meter in a humid environment with steam etc., or in the air with explosive gas.

1.13 When using the test leads, please hold your finger behind the finger protective equipment of the probe.

1.14 Please connect the neutral wire or ground wire first under measurement, and then connect the live wire. When the measurement ends, please disconnect the live wire first, and then disconnect the neutral wire and ground wire.

1.15 Before opening the shell or battery cover, remove all probes or test leads. Do not use the meter when it is disassembled or the battery cover opened.

1. Technical characteristics

Accuracy is effective within one year after calibration

Ambient temperature: 18℃~ 28℃, relative humidity: ≤80%%

DCV

Range Resolution Accuracy
400mV 0.1mV ±(0.5%+5d)
4V 0.001V
40V 0.01V
400V 0.1V
600V 1V

Input impedance: 10MΩ

Overload protection: 600V; Max. measuring voltage: 600V

ACV

Range Resolution Accuracy
4V 0.001V ±(1.0%+5d)
40V 0.01V
400V 0.1V
600V

1V

ACA

Range Resolution Accuracy
4A 0.001A

50~60Hz:±(2.5%+5d);

Other: ±(3.0%+10d)

40A 0.01A
400A 0.1A
600A 1A

Max. measuring current: 600A; Frequency range: 40Hz ~ 1kHz; Response: True RMS

Resistance

Range Resolution Accuracy
400Ω 0.1Ω ±(1.0%+5d)
4kΩ 0.001kΩ
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ
40MΩ 0.01MΩ

Overload protection: 250V

Capacitance

Range Resolution Accuracy
10nF 0.001nF ±(4.0%+5d)
100nF 0.01nF
1000nF 0.1nF
10mF 0.001mF
100mF 0.01mF
1000mF 0.1mF
10mF

0.001mF

Frequency / duty cycle

Range Resolution Accuracy
10Hz 0.001Hz ±(1.0%+3d)
100Hz 0.01Hz
1000Hz 0.1Hz
10kHz 0.001kHz
100kHz 0.01kHz
1000kHz 0.1kHz
10MHz 0.001MHz

±(3.0%+3d)

Temperature

Range Resolution Accuracy
1℃ -20℃~ 0℃ ± 3℃
0℃ ~ 400℃ ± (2.0%+3)
400℃ ~ 1000℃
1℉ -4℉~ 32℉ ± 5℉
32℉~ 752℉ ± (2.0%+3)
752℉~ 1832℉
Send your message to this supplier
Send Now

10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp

Ask Latest Price
Watch Video
Brand Name :
VICTOR
Model Number :
VICTOR 606D
Certification :
CE
Place of Origin :
CHINA
MOQ :
300
Payment Terms :
T/T, Western Union, L/C,Paypal
Contact Supplier
video
10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp
10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp
10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp
10mF 4000 Counts Multimeter Pocket Clamp Meter 600A 10kHz With Temp

XI'AN BEICHENG ELECTRONICS CO.,LTD

Site Member
5 Years
Since 1980
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
200~500
Certification Level :
Site Member
Contact Supplier
Submit Requirement