Specifications
Brand Name :
VICTOR
Model Number :
VICTOR 1800
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
USD808/pc
Payment Terms :
T/T, Western Union, L/C, Paypal
Supply Ability :
10000PCS
Delivery Time :
5 to 30 days
Packaging Details :
Color box ,1pcs/Carton ,9.8KG/Carton
Color :
Black and Orange
Packing :
color box
Weight :
Approx 496g
Display Mode :
3.5-inch LCD display
Dimension :
145mm×60mm×48mm
Power :
DC 3.7V rechargeable Li-battery
Resolution :
1°;0.1Hz
Product Name :
Wireless High Voltage Satellite Remote Distance Phase Detector
Description

VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector

VICTOR 1800 Wireless High Voltage Satellite Remote Distance Phase Detector Frequency Phase Sequence Inspection 32 Tracking Channels

Brief Introduction

Wireless high voltage satellite remote distance phase instrument, also known as wireless high voltage satellite remote distance phase detector device, is composed of X receiver, Y receiver, X detector, Y detector, telescopic insulation rod and so on.

It can carry on the detecting phase of the power grid, cabinet, the middle cabinet and the switch cabinet, and has the function of the ordinary phase detecting instrument. The satellite timing core can achieve ultra long distance detected phase, basement phase detecting and underground phase detecting , and the time accuracy is less than 30nS.

The receiver uses a 3.5 inch real color LCD screen and a multi mode satellite timing module in one compose of six to support a variety of satellite navigation systems, including China's BDS (Beidou satellite navigation system), American GPS, Russian GLONASS, EU GALILEO, Japanese QZSS and satellite enhancement system SBAS (WAAS, EGNOS, GAGAN, MSAS).

It contains 32 tracking channels, which can receive GNSS signals from six satellite timing systems at the same time, and realize alliance time service to ensure accurate phase detecting.

The receiver displays live-time phase and frequency on the same screen, and has the voice prompt of "X signal normal, Y signal normal, phase to phase, phase difference" and so on, which is clear and intuitive. The distance of the common phase detector in the open ground is 160m around and the distance of the satellite timing phase detector is more than 500km.

It can be used for the full intelligent phase detecting of the voltage line of 10V to 550kV, and can also be used for the low voltage induction point and the high voltage line and the fully sealed circle grid power cabinet, in which the naked wires voltage under 35kV can directly contact the phase detector and the bare wire above the 35kV adopts non-contact, means detector is gradually close to the measuring wire, complete the phase detecting when received the induction of electric field signal , so there is no direct contact with hi-voltage wire, more safe! The phase detecting instrument also has the functions of high voltage electroscope, high voltage phase meter and high voltage phase sequence table. It can be used for power inspection, phase sequence test, transformer group judgement and so on.

Technology specification

Function Wireless high voltage-satellite timing-phase detecting, frequency, phase, phase sequence, and electricity inspection.
Power DC 3.7V rechargeable Li-battery,USB charge port,continually working 10h
Phase detecting Satellite second pulse precision mode, satellite timing mode, common mode
transmission mode 315MHz,433MHz wireless transfer
Distance of phase detecting Satellite timing phase detector distance up to 500km
Common phase detector: 160m
Display mode 3.5 LCD display
Range Rank of phase detecting:AC 10V~550kV
Phase degree:0°~360°
Frequency:45Hz~75Hz
Resolution 1°;0.1Hz
Accuracy (23℃±5℃,80%RH below) Satellite phase Detector degree tolerance:≤±5°
Common detector tolerance:≤±10°
Frequency tolerance:≤±2Hz
Phase judgement

Same phase: XY receiver detected phase degree variance at range of 0°~30° ;

Heterogenous phase: XY receiver detected phase degree at range of 90°~120° or 210°~270°

Phonetic function Voice report: Same phase, Heterogenous phase, normal X signal,normal Y signal
Satellite Timing validity Once the satellite timing successfully, validity time over 30mins to meet the underground phase detecting.
Insulation rod length Stretched length 5m;carrying on length 1m
Method of phase detecting Contact:35kV below bare wire or 110kV with insulation skin.( testing with insulation rod)
Non-contact:35kV above bare wire or 110kV above.(testing with insulation rod)
Voice indication The sound of the probe "Du - Du - Du" buzz
Mode switch Automatic shift
Sampling speed 2times/sec
Connecting satellite time After turning on detector, 1st search satellite takes 3min about, 2nd search satellite takes 30sec, The follow-up heat starts searching satellite time about 1 second, detector positive set up and keep level of heaven
Timing accuracy Less 30nS
Instrument size Detector: LxWxT 145mm×60mm×48mm
Receiver:LxWxT 250mm×100mm×40mm
Background brightness adjust

press ↑ ↓ adjust background brightness

Induction strength control According to the different electric field of induction, the detector can automatically control magnification and facilitate the detecting phase in dense wire area.
Hold data 1st Press HOLD to save date,2nd cancel date
Quit Press ESC button return interface
Data lookup Press ENTER look up data, press ↑↓ review
Symbol of satellite searching Dynamic display “----”symbol at period of search satellite
Automatically power off Standby 30min, then power off automatically for power saving
Rated current detector:35mA max;receiver:300mA max
Batter voltage The detector low battery symbol display when voltage lower 3.2V, remind of charge battery
Instrument weight detector:205g(contains battery)
receiver:395g(contains battery)
Insulation rod:1.45kg
Total weight:12.6kg(contains meter box)
Working humiture -10℃~40℃;80%Rh below
Storage humiture -10℃~60℃;70%Rh below
interfere No interfere except especially Strong magnetic field, no interfere except same frequency 433MHz,315MHz
Insulation strength Insulation rod:AC 110kV/rms(5sections after stretched)
detector:2000V/rms( rod connection ends to detector top)
receiver:2000V/rms(outer shell two ends )
structure Anti leak type II,IP63
Proper Standard GB13398 92, GB311.1 - 311.6 - 8, 3DL408 91 standard and national new electric power industry standard "DL/T971-2005 for universal technical conditions for portable 1kV to 35kV portable phase detector apparatus for live work"
Ideal for IEC61481-A2:2004;IEC 61243-1 ed.2:2003 standard


Send your message to this supplier
Send Now

VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector

Ask Latest Price
Brand Name :
VICTOR
Model Number :
VICTOR 1800
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
USD808/pc
Contact Supplier
VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector
VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector
VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector
VICTOR 1800 Electric Power Tester Satellite Remote Distance Phase Detector

XI'AN BEICHENG ELECTRONICS CO.,LTD

Site Member
5 Years
Since 1980
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
200~500
Certification Level :
Site Member
Contact Supplier