Specifications
Brand Name :
VICTOR
Model Number :
VICTOR 606+ 606A+ 606B+ 606C+
Certification :
CE
Place of Origin :
CHINA
MOQ :
300
Price :
VICTOR606+ USD9/pc VICTOR606A+ USD10/pc VICTOR606B+ USD11.3/pc VICTOR606C+ USD20/pc
Payment Terms :
T/T, Western Union, L/C,Paypal
Supply Ability :
10000 pc available
Delivery Time :
5-30 days
Packaging Details :
Color box ,30pcs/Carton ,13KG/Carton
Color :
Black and orange
Weight :
Approx 236g
Packing :
Color box
Product Size :
207×72×39mm
Operation way :
Auto range
Clamp size :
30 mm
Battery :
1.5V*2
Display :
5999 Counts
Description

VICTOR 606+ 606A+ 606B+ 606C+ Digital Clamp meter 5999 counts AC/DC 600V 600A Clamp multimeter with Live NCV Flashlight True-RMS function


1. SUMMARIZE
This meter is a handheld automatic range digital multiemter which driven by battery. It can be used to measure such parameters as DCV, ACV, DCA and ACA, Resistance, Continuity Buzzer, Diode, Frequency etc.

2. SAFETY OPERATION RULE
The meter’s design is in accordance with the CE certification, meets the standard of IEC61010. Read the following before operation.
2-1. Input over range is prohibited in each range during the test.
2-2. Place the function knob to the proper range before measurement, in case damage the meter, do not switch the range during measurement.
2-3. Voltage less than 36V is safety voltage. To avoid electric shock, be careful when measuring voltage higher than 36V DC, 25V AC.
2-4. Don’t input voltage under the resistance, capacitance, diode, continuity test, frequency measurement.

5. TECHNICAL CHARACTERISTIC

FUNCTION 606+ 606A+ 606B+ 606C+ Accuracy
DCV 200mV/2V/20V 600mV/6V/60V 600mV/6V/60V 600mV/6V/60V ±(0.5%+7)
200V 600V 600V 600V ±(1.0%+ 20)
600V / / / ±(1.2%+ 20)
ACV 2V/20V 6V/60V 6V/60V 6V/60V ±(0.8%+ 10)
200V 600V 600V 600V ±(1.2%+ 25)
600V / / / ±(1.5%+25)

LOW INPEDANCE

ACV

2V/20V 6V/60V 6V/60V 6V/60V ±(0.8%+ 10)
200V 300V 300V / ±(1.2%+25)
300V / / / ±(1.5%+ 25)
/ / / 300V ±(1.0%+12)
ACA 2A 6A 6A / ±(4.0%+ 50)
20A 60A 60A / ±(4.0%+ 35)
200A/600A 600A 600A / ±(4.0%+15)
/ / / 60A/600A ±(4.0%+10)
DCA / / / 60A/600A ±(4.0%+10)
RESISTENCE

200Ω/2kΩ/20kΩ/

200kΩ/2MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

±(1.0%+ 5)
20MΩ 20MΩ 20MΩ 20MΩ ±(1.5%+15)
/ 60MΩ 60MΩ 60MΩ ±(2.5%+20)
CAPACITANCE / 6nF 6nF 6nF ±(5.0%+40)
/ 60nF/600nF/6uF 60nF/600nF/6uF 60nF/600nF/6uF ±(5.0%+ 10)
/ 60uF/600uF/6mF 60uF/600uF/6mF 60uF/600uF/6mF
FREQUENCY /

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

10Hz/100Hz/1kHz/10kHz/

100kHz/ 1MHz/10MHz

±(0.3%+3)
TEMPERATURE / /

-20℃~1000℃

(-4-1832)℉

-20℃~1000℃

(-4-1832)℉

/

Display method

LCD display

5999 count

Max/Min
Maximum display

5999 count

(606+ 1999count)

Low Z
Diode measurement Working temperature and humidity (0-40) ℃ <75%
Data retention Storage temperature and humidity (-10~50)℃<80%
NCV measurement Automatic shut-down About 15 minutes
Fire detection Over-range display the highest digit displays OL
Low voltage warning Unit symbol
Flashlight lighting Open jaws 35mm
True effective value input resistance 10MΩ
INRUSH 606C+ only Sampling rate 3 times/sec
VFC 606C+ only power supply Two AAA batteries
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Send your message to this supplier
Send Now

VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

Ask Latest Price
Brand Name :
VICTOR
Model Number :
VICTOR 606+ 606A+ 606B+ 606C+
Certification :
CE
Place of Origin :
CHINA
MOQ :
300
Price :
VICTOR606+ USD9/pc VICTOR606A+ USD10/pc VICTOR606B+ USD11.3/pc VICTOR606C+ USD20/pc
Contact Supplier
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight

XI'AN BEICHENG ELECTRONICS CO.,LTD

Site Member
5 Years
Since 1980
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
200~500
Certification Level :
Site Member
Contact Supplier
Submit Requirement