Specifications
Brand Name :
VICTOR
Model Number :
4105C
Certification :
CE
Place of Origin :
CHINA
MOQ :
10pcs
Price :
negotiable
Payment Terms :
T/T, Western Union, L/C,Paypal
Supply Ability :
10000 pc available
Delivery Time :
5-30 days
Packaging Details :
Color box ,1pcs/Carton ,5.5KG/Carton
Color :
Black and orange
Weight :
Approx4520g
Packing :
Color box
Max display :
4-digital super-large LCD display
LCD size :
128*75mm
Power dissipation :
Electricity cost (no-lode)≤800mw
Battery :
DC 9V
Product size :
280*260*160mm
Description

VICTOR 4105C Digital Ground Resistance Tester Soil Resistivity Electrical Tester Light Protection Inspection Large LCD Display

VICTOR4105C Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.

VICTOR4105C Earth Resistance Soil Resistivity Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 300 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, alarm indicator, and with the functions like historical data access, reading, preservation, report forms, printing and so on.

VICTOR4105C Earth Resistance Soil Resistivity Tester also named: Precise Earth Resistance Tester, 4-pole Earth Resistance Tester, 2/3/4-pole Earth Resistance Tester, Soil Resistivity Tester.

2.Technical Specifications

Influence Quantity Base Condition Working Conditions Remark
Ambient Temp 23℃±1℃ -10℃-40℃ ----
Ambient Humidity 40%-60% <80% ----
Working Voltage 9V±0.1V 9V±1.5V rC,rP
Auxiliary Earth Resistance <100Ω <30kΩ ----
Interference Voltage no <20V ----
Interference Current no <2A
Electrode Distance when measuring R a>5d a>5d ----
Electrode Distance when measuring ρ a>20h a>20h ----

2. General Specification

Function Measurement of 2/3/4-pole earth resistance, soil resistivity, earth voltage, AC voltage
Power Supply DC 9V (Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
Measurement Range Earth Resistance: 0.00Ω-30.00kΩ
Soil Resistivity: 0.00Ωm-9000kΩm
Measuring Mode Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement
Measuring Method

Earth Resistance: rated current change-pole method, measurement current 20mA Max

Soil Resistivity: 4-pole measurement (Wenner method)

Earth Voltage: average rectification(between P(S)-ES)

Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current AC 20mA max
Open-circuit Test Current AC 40V max
Test Voltage Wave Sine wave
Electrode Distance Range Can be set 1m-100m
Shift Earth Resistance: 0.00Ω-30.00kΩ, automatic shift
Soil Resistivity: 0.00Ωm-9000kΩm, automatic shift
Backlight Blue screen backlight, suitable for dim places
Display Mode 4-digital super-large LCD display, blue screen backlight
Measuring Indicator During measurement, LED flash indicator, LCD count down display, progress bar indicator
LCD Frame Dimension 128mm×75mm
LCD Window Dimension 124mm×67mm
Dimension L×W×H: 215mm×190mm×95mm
Standard Test Wire 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire 2 wires: each for red 1.6m and black 1.6m
Auxiliary Earthing Rod 4 rods: Φ10mm×150mm
Measuring Rate Earth voltage: about 3 times/second
Earth resistance, soil resistivity: about 5 seconds/time
Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Line Voltage below AC 600V
RS232 Interface Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.
Communication Wire One piece of RS232 communication wire, with length 1.5m
Data Storage 300 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full
Data Hold Data hold function: “HOLD” icon display
Data Access Data read function: “READ"
Overflow Display Exceeding measuring range overflow function: “OL” icon display
Interference Test Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V
Auxiliary Earthing Test Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
Battery Voltage When battery voltage decreases to about 7.5V, battery voltage low icon will display, reminding to replace battery.
Power Consumption Standby: about 20mA (Backlight shut off)
Boot and with backlight: about 45mA (25mA without backlight)
Measurement: about 100mA (Backlight shut off)
Weight Total weight: 4.5kg (including package)
Tester: 1443g (including battery)
Testing wires: 1560g
Auxiliary earthing rods: 935g (4pcs)
Working -10℃-40℃, below 80%rh
Storage temperature & humidity -20℃-60℃, below 70%rh
Overload Protection Measuring earth resistance: between each interfaces of C(H)-E,P(S)-ES, AC 280V/3 seconds
Insulation Resistance Over 20MΩ (between it is 500V)
Withstanding Voltage AC 3700V/rms (Between circuit and enclosure)
Electromagnetic Features IEC61326(EMC)
Protection Type IEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004

3. Intrinsic error and performance indicators under base conditions

Category Measurement Range Intrinsic Error Resolution

Earth Resistance

(R)

0.00Ω-30.00Ω ±2%rdg±3dgt 0.01Ω
30.0Ω-300.0Ω ±2%rdg±3dgt 0.1Ω
300Ω-3000Ω ±2%rdg±3dgt
3.00kΩ-30.00kΩ ±4%rdg±3dgt 10Ω

Soil Resistivity

(ρ)

0.00Ωm-99.99Ωm

According to the precision of R

(ρ=2πaR

a:1 m-100m,

π=3.14)

0.01Ωm
100.0Ωm-999.9Ωm 0.1Ωm
1000Ωm-9999Ωm 1Ωm
10.00kΩm-99.99kΩm 10Ωm
100.0kΩm-999.9kΩm 100Ωm
1000kΩm-9000kΩm 1kΩm
Earth Voltage AC 0.0-600V ±2%rdg±3dgt 0.1V

Note: 1. When rC max or rP max, additional error≤±3%rdg±5dgt.

(rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ)

2. When 5V interference voltage, additional error≤±5%rdg±5dgt.

IEC61557 VICTOR 4105C Digital Ground Resistance Tester

IEC61557 VICTOR 4105C Digital Ground Resistance Tester

IEC61557 VICTOR 4105C Digital Ground Resistance Tester

IEC61557 VICTOR 4105C Digital Ground Resistance Tester

Send your message to this supplier
Send Now

IEC61557 VICTOR 4105C Digital Ground Resistance Tester

Ask Latest Price
Brand Name :
VICTOR
Model Number :
4105C
Certification :
CE
Place of Origin :
CHINA
MOQ :
10pcs
Price :
negotiable
Contact Supplier
IEC61557 VICTOR 4105C Digital Ground Resistance Tester
IEC61557 VICTOR 4105C Digital Ground Resistance Tester
IEC61557 VICTOR 4105C Digital Ground Resistance Tester

XI'AN BEICHENG ELECTRONICS CO.,LTD

Site Member
5 Years
Since 1980
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
4000000-5000000
Employee Number :
200~500
Certification Level :
Site Member
Contact Supplier
Submit Requirement