Specifications
Brand Name :
APC
Model Number :
GVL200K500DS
Certification :
CE EAC RCM
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T
Lead time :
Special Order - Call for Quoted Lead Times
Main Input Voltage :
400 V 3 phases
Other Input Voltage :
380 V 415 V
Other Output Voltage :
Other Output Voltage
Battery voltage :
+/- 216...+/- 300 V
Weight :
688 kg
Dimensions :
2117 x 1000 x 800 mm
Topology :
Double Conversion Online
Efficiency :
Up to 96%
Display :
LCD
Communication Ports :
USB, RS232, SmartSlot
Frequency :
50/60Hz
Form Factor :
Tower
Description

Features

Galaxy VL is a highly efficient, compact, modular, and scalable 200-500 kW (400 V/480 V) three-phase uninterruptible power supply (UPS) available worldwide that delivers top performance for medium, large, and edge data centers, as well as critical infrastructure in commercial and industrial facilities.

Its industry-leading, compact, high-density technology, and fault-tolerant architecture maximize availability, operational efficiency, and critical load protection while minimizing total cost of ownership (TCO). Thanks to patented technologies, this UPS delivers up to 99% efficiency in ECOnversion™ mode and up to 97% efficiency in double conversion mode.

Galaxy VL’s scalability enables you to pay-as-you grow, reducing both capital investment and TCO. You can buy the power modules you need up-front, and enjoy optimized operating efficiency, then add power modules with Live Swap as demand grows. The modular design also enables N+1 internal redundancy, which multiplies by 10 the system’s availability with no extra footprint.

Galaxy VL is compatible with Lithium-ion batteries. With our Schneider Electric Lithium-ion battery solution, classic VRLA, or NiCd batteries, critical loads have highly predictable runtimes.

Galaxy VL is EcoStruxure™ connected to give you peace of mind anytime, anywhere. Start-up service is included to optimize your system’s performance, quality, and safety. With Live Swap, modular design, and superior reliability, Galaxy VL is the ideal backbone for your critical infrastructure.

Benefits

Availability
  • Flexible DC bus - Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.
  • Parallel-redundant capable - Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Parallel-capacity capable - Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Robust operation - No power derating in kW up to 40 degrees C or 104 degrees F.
  • Compatible with Schneider Electric's lithium ion battery solution - Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. br /Click a href="http://www.schneider-electric.com/b2b/en/solutions/system/s4/data-center-and-network-systems-lithium-ion-battery/index.jsp"; target="_blank"here/a for more details.
  • Modular UPS design - Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
  • Embedded Network Management Card - Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.
Serviceability
  • Front-access servicing - Simplifies installation and UPS maintenance while minimizing space requirements.
  • Multiple levels of service offers - With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
  • EcoStruxure IT Expert - From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visit a target="_blank" href="http://www.ecostruxureit.com"ecostruxureit.com/a.
Total cost of Ownership
  • High efficiency in double conversion mode - Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
  • Input Power Factor Correction - Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Compact UPS - High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
  • ECOnversion mode - Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.

Overview
Presentation Highly efficient, modular, high-density 200kW (400/480V) 3-phase UPS that is scalable up to 500kW. It delivers top performance for medium, large, and edge data centers, as well as critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service.
Lead time Special Order - Call for Quoted Lead Times

Main
Main Input Voltage 380 V 3 phases
400 V 3 phases
415 V 3 phases
440 V 3 phases
480 V 3 phases
Main Output Voltage 380 V 3 phases
400 V 3 phases
415 V 3 phases
440 V 3 phases
480 V 3 phases
Other Output Voltage 400 V
480 V
Rated power in W 200 kW
Rated power in VA 200 kVA
Battery type Li-Ion (Lithium-Ion)
VRLA
Ni-Cd (Nickel-Cadmium)

Batteries & Runtime
Efficiency View Efficiency Graph
action_new_window
Discharge battery voltage 384 V

General
Number of power module 4
Number of power module free slots 6
Redundant Yes

Physical
Colour White
height 197 cm
Width 85 cm
Depth 92.5 cm
Net weight 550 kg

Input
Network frequency 40...70 Hz
Max short time withstand current 65 kA
Input harmonic distortion Less than 5 % for full load
Load power factor 0.5 leading to 0.5 lagging without derating

Output
Maximum configurable power in W 500 kW
Crest factor 3
Output harmonic distortion < 1% linear load and < 5% non-linear load
Output overload operation 10 minutes at 125% and 60 seconds at 150%
Maximum configurable power in VA 500 kVA

Conformance
product certifications IEC 62040-1-1
UL 1778 5th edition
IEC 62040-2
IEC 62040-3
VFI-SS-111
FCC Class A
ENERGY STAR V2.0 (USA)
Standards IEC 60721-4-2 level 2M2

Environmental
ambient air temperature for operation 0…40 °C
Relative humidity 0…95 % non-condensing
Operating altitude 0...3000 m
Ambient air temperature for storage -25…55 °C
Storage Relative Humidity 10…80 % non-condensing
IP degree of protection IP20

Communications & Management
control panel Touch screen LCD user interface

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2145 mm
Package 1 Width 1100 mm
Package 1 Length 950 mm
Package 1 Weight 620 kg

Contractual warranty
Warranty 1 year on-site repair or replace with factory authorized Start-Up

APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480VAPC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V

Send your message to this supplier
Send Now

APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V

Ask Latest Price
Watch Video
Brand Name :
APC
Model Number :
GVL200K500DS
Certification :
CE EAC RCM
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T
Contact Supplier
video
APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V
APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V
APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V
APC Data Center And Facility 3 Phase Galaxy VL UPS Scalable 200 To 500kW 400/480V

Visench Technology Co., Ltd.

Verified Supplier
2 Years
shenzhen
Since 2006
Business Type :
Manufacturer
Total Annual :
20000000-50000000
Employee Number :
1000~2000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement