Industry-leading protection
High density, double-conversion On-Line power protection delivers clean power with zero transfer time, and helps guard your critical electronics and data against dangerous power conditions and disturbances.
Lead time | Usually in Stock |
---|
Run time for load WMin-max: 140-1800 W | 2min 10s |
---|---|
Main Input Voltage | 230 V |
Other Input Voltage | 220 V 240 V |
Main Output Voltage | 230 V |
Other Output Voltage | 220 V 240 V |
Kw Rating | 1800 W |
Rated power in VA | 2000 VA |
Input Connection Type | IEC 60320 C20 |
output connection type | 6 IEC 60320 C13 2 IEC Jumpers |
Number of rack unit | 2U |
Number of cables | 1 |
Provided equipment | CD with software Smart UPS signalling RS-232 cable User Manual |
Run Time | View Runtime Graph |
---|---|
Battery Type | Lead-Acid battery |
Included Battery Modules | 0 |
Battery Slots Empty | 0 |
Typical recharge time | 4 h |
RBC Quantity | 1 |
Battery Charge Power (Watts) | 79 W rated |
Battery Life | 3…5 year(s) |
Replacement battery | RBC31 |
Extendable Run Time | 1 |
Topology | Double Conversion Online |
---|---|
Number of power module | 1600 |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
color | Black |
---|---|
Height | 17.01 in (43.2 cm) |
Width | 3.35 in (8.5 cm) |
Depth | 19.02 in (48.3 cm) |
Net Weight | 55.12 lb(US) (25 kg) |
Mounting Location | Front |
Mounting preference | Lower |
Mounting Mode | Rack-mounted with kit |
Two post mountable | 0 |
USB compatible | No |
Input Frequency | 50/60 Hz +/- 5 Hz auto-sensing |
---|---|
Efficiency at full load | 160...280 V |
Maximum configurable power in VA | 2000 VA |
---|---|
Max Configurable Power (Watts) | 1800 W |
Output Frequency (sync to mains) | 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 sync to mains |
Wave type | Sine wave |
Efficiency at full load | 90 % full load) |
Harmonic distortion | Less than 3% |
Crest factor | 3 : 1 |
Bypass type | Built-in Bypass |
Additional information | Configurable for 220 : 230 or 240 nominal output voltage |
Product Certifications | C-tick CE GOST VDE |
---|---|
Standards | EN/IEC 62040-1:2019/A11:2021 EN/IEC 62040-2:2006/AC:2006 EN/IEC 62040-2:2018 |
Ambient Air Temperature for Operation | 32…104 °F (0…40 °C) |
---|---|
Relative Humidity | 0…95 % non-condensing |
Operating altitude | 0...10000 ft |
Ambient Air Temperature for Storage | -4…122 °F (-20…50 °C) |
Storage Relative Humidity | 0…95 % non-condensing |
Storage altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic level | 50 dBA |
heat dissipation | 543 Btu/h |
IP degree of protection | IP20 |
Free slots | 1 |
---|---|
Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Emergency Power Off (EPO) | Optional |
Surge energy rating | 420 J |
---|---|
Filtering | Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : m |
GTIN | 731304205487 |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 11.26 in (28.6 cm) |
Package 1 Width | 23.39 in (59.4 cm) |
Package 1 Length | 24.80 in (63 cm) |
Package 1 Weight | 65.74 lb(US) (29.82 kg) |
Warranty | 2 years repair or replace, optional on-site warranties available, optional extended warranties available |
---|