Screw Interface Breakout Module DIN Rail Mounting For Home Intelligent Control
1. A full range of modular structures: The series of products that are designed as modular structures in the control cabinet's wiring accessories, including signal input and output, power distribution, etc., adopt standard installation dimensions, transparent components and arrangements, indicating at a glance, both beautiful and Fast.
2,Comprehensive functions: It has multiple functions such as signal isolation and driving, loop power supply, card power supply, signal indication, alarm indication, loop protection, power protection, signal transfer, etc. It can support multiple brand safety barriers and isolators, and comprehensive Improve the quality of wiring.
3. Simplified design and wiring: The type of jumper on the board solves the problem of differentiation and complication of wiring between external devices and system cards. The signal transmission and the power supply are organically combined. The same card can connect different types of instruments and signals. Only the jumper on the board is changed and the line node is reduced. The in-platform construction drawings are simplified into simple forms, which reduce the dependence of the complex lines on the drawings and thoroughly simplify the design of the construction drawings and the process of wiring in the trays.
4. Eliminating the terminal block: The plug-in terminal block provided on the external terminal can facilitate the maintenance of the terminal. The replacement of the terminal board may not remove the connection. The spring terminal has the characteristics of quick connection, reliable crimping and low failure rate. The 1~2.5mm2 wire can be directly connected to the terminal board, and there is no need to specially equip the terminal block. The internal terminal uses a dedicated interface and uses special cables to quickly plug in the PLC or DCS.
5, all-round protection, do not remove the line to stop the table, omitting the distribution switch, to avoid misuse: Each signal circuit is equipped with a convenient insurance to facilitate the provision of a full range of security, the user no longer need to be equipped with power distribution for external devices Switch and fuse terminals. Specially solves the problems of DCS and PLC system peripheral meter stopwatch. To repair and dismantle the external equipment, it is necessary to remove the insurance without removing the wire, which is fast, efficient, safe and reliable to prevent misconnection. The power circuit uses overvoltage, overcurrent, and reverse polarity protection measures to ensure the safe operation of the system equipment.
♦ Technical data
Model | JR-50TBC |
Connector type | IDC(MIL) |
I/O poles | 50 |
Wiring method | Euro terminal (slotted screws) *Japanese terminal (Phillips screws) can be customized |
Rated current | 1A |
Rated voltage | DC24V |
Insuration resistance | 100MΩ min. (at 500VDC) |
Dielectric strength | 500VAC 1min |
Ambient operating temperature | -20℃~+55℃ |
Applicable wires | AWG 22-16(0.3~1.25mm2),6~7mm |
Suitable Uses | Panasonic FPΣ PLC |
Dimensions(LxWxH) | 49×46mm |
Mounting | DIN rail |