GINRI SVR1000 Single Phase Monitoring Over Under Voltage Relay
The Features of SVR10000
-- Powered by the measuring circuit
-- Built-in LCD and keypad afford a precise,digital setting
-- Compact modular 43mm housing
-- Adjustable over- and undervoltage threshold
-- Independent adjustable delay time for overvoltage, undervoltage
-- 1 CO & 1NC contacts
-- Fault recording with last 3 faults
♦ Protective Functions
-- Overvoltage
-- Undervoltage
♦ Typical Applications
• Pumps • Fans
• Blowers • Motors
• Compressors
♦ Approvals
• CE • CCC
♦ Technical data
Model | SVR1000/D12 | SVR1000/AD48 | SVR1000/AD220 | ||
Measuring circuit | A1+,A2- | ||||
Rated voltage | DC 12V | AC/DC 24~48V,50/60Hz | AC/DC 110~240V,50/60Hz | ||
Monitoring functions | overvolatege, undervoltage | ||||
Overvoltage setting range | DC 9.0~18.0V adjustable | AC/DC 20.0~80.0V adjustable | AC/DC 50.0~300V adjustable | ||
Undervoltage setting range | DC 9.0~18.0V adjustable | AC/DC 20.0~80.0V adjustable | AC/DC 50.0~300V adjustable | ||
Voltage hysteresis | 0.1~6.0V adjustable | 0.1~30.0V adjustable | 1.0~90.0V adjustable | ||
Delay time for overvoltage and undervoltage | 0.1-999s adjustable | ||||
Reset mode | Manual/ Automatic/Automatic with power-on delay | ||||
Delay time for reset | 0.1-999s adjustable | ||||
Indicators | LCD indicating voltage,operationand fault status | ||||
Output contacts | 1 CO & 1NC | ||||
Contact capacity | 6A ,250VAC | ||||
Dimensions (H x W x D) | 80×43×54mm | ||||
Mounting | DIN rail |
1. Overvoltage protection: When the grid voltage is greater than the set value, the protection function is activated. The action threshold setting range is OFF-50-3000V, the action mode is the definite time limit, and the action time setting range is 0.1-999s. After the protection action, the grid voltage returns to less than the set value of 10V or more.
2. Undervoltage protection: When the grid voltage is less than the set value, the protection function is activated. The action threshold value setting range is 500-300V-OFF, the action mode is the definite time limit, and the action time setting range is 0.1-999s. After the protection action, the grid voltage returns to greater than the set value of 10V or more.
3.Reset mode: You can set the reset mode in auto reset or manual reset
4.Fault record: Non-volatile memory technology is used to record faults when overvoltage, undervoltage. Even if the product is completely powered off, the fault information can be memorized and the fault is easily queried. Conducive to the analysis of the cause of the fault after the accident, easy to troubleshoot