Specifications
Brand Name :
Dongyuan
Model Number :
L1PB26-NC
Certification :
ISO14001,ISO9001,OHSAS18001
Place of Origin :
China,Shunde
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
10000pcs per month
Delivery Time :
30days after receiving the deposit
Packaging Details :
Each product in plastic bag which comes with the product instructions and foam packaging, then carton packaging outside with another thicker plastic bag.
Origin :
China
Pressure :
Low Pressure
Structure :
Water Tube
Water Circulation :
Forced Circulation
Packing Size(Mm) :
855*470*390
Exchanger :
One heat exchanger
Description

Wall Mounted Installation Digital Display For Room Heating And Sanitary Hot Water Gas Combi Boiler

Technical data

Model Number LIPB18 L1PB20 L1PB24
Gas Type NG/LPG
Rated Gas Pressure(Pa) 2000/2800
Rated Gas Input(kw) 18 20 24
Rated Gas Output(kw) 15.9 17.6 21.1
Efficiency Under Rated Heat Input(%) Above88%
Power Supply 20-50HZ
Electric Power(W) 110 110 110
Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60
Heating Area(㎡) 70-140 80-160 100-200
Lift Of pump(m) 5 5 5
Application Water Pressure(Mpa) 0.1-0.3
Expansion Tank Capacity(L) 6 6 6
Preset Pressure Of Expansion Vessel(Mpa) 0.1
Water Circulation Type Airtight Forced Circulation
△T=25℃ Hot Water Supply(kg/min) 9 10 12
△T=30℃ Hot Water Supply(kg/min) 7.5 8.3 10
Temp.Range Of DHW Supply(℃) 30-60
Applicative Water Pressure(mpa) 0.03-0.8
The Minimum Starting Flow (L/min) 2
The Minimum Closed Flow(L/min) 1.6
Connections(mm) For Gas&Heating Water Pipes:G3/4 For DHW Pipes:G1/2
Air Input/Exhaust Duct(mm) φ60/φ100
Sparated Input/Exhaust Duct(optional) φ80/φ100
The length Of Flue Dust(m) 1
Noise On Working(DB) <42
Exhaust Type Forced Exhaust
Ignition Type Integrated Automatic Ignition
Temperature Control Gas Proportional Adjustment
Product Dimensions(mm) 740*400*305
Packing Dimensions(mm) 865*470*385
Container(20GP/40GP/40HQ) 17//357/434

- Inteligent constant temperature control will provide easeful warmth for your rooms and comfortable

shower water anytime.

- PCB is insensitive to the electric polarity and fluctuations of voltage AC 160-242 Volt.

- Indication of temperatures, working modes, power level and error codes on the color multifunctional LED display.

- Frost protection: Burner and pump will be switch on automatically by danger of freezing. It is allowed to use

antifreeze liquid instead of water in the heating system.

- Universal main PCB fully compatible with other models of Dongyuan boilers.

- Four section timer.

- Intelligent and economical control system.

- The original modular design, assembly and disassembly is simple, fault memory function, convenient for the

rapid diagnosis of after sales personnel.

- With normal mode, state mode, diagnostic mode, failure mode, can quickly provide comfortable hot water

in a very short time.

- Delay operation to prevent overheating repeatedly start.

- Multiple security devices ensure high safety grade including anti-freezing protection, overheat protection,

by-pass protection, and so on.

- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation

process begin earlier and by higher return line temperature(about 57℃)

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant,

with great optimization of gas consumption.

- Integrated pump, expansion tank, heating safety valve,manometer,automatic air exhaust device.

- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use

antifreeze liquid instead of water in the heating system.

- Support smooth control with open therm room thermostat from any producer.

- Easy operation. With 2 knobs for mode choosing and function option,another 5 indicating lights for indicating

working condition of boiler.

- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the gas-air mix.

- Indication of temperatures, working modes, current burner power and error codes on the color multifunctional LED display.

- Various capacity available. Input capacity(20kw,24kw,28kw,32kw) can match with different house type.

- Various structure available,suitable for different using condition.

- Can be connected with room thermostat or remote controller which providing more function options.

- Two modifications: Bi-thermal pipe-in-pipe copper heat exchanger or with separate plate DHW heat exchanger.

-Till 24kw heating output, till 14.2L/min hot water(DHW)with T=25℃

- Frost protection: Burner and pump will be switch on automatically by danger of freezing. It is allowed to use antifreeze liquid

instead of water in the heating system.

- Steady ignition and work by low inlet gas pressure from 3mbar, full output by inlet gas pressure from 13mbar and higher.

- Universal main PCB fully compatible with other models of Dongyuan boilers.

- Supports smooth control with Open Therm room thermostat from any producer.

Digital Display Home Heating Boilers , Gas Fired Hot Water Boiler Wall Mounted Installation

Digital Display Home Heating Boilers , Gas Fired Hot Water Boiler Wall Mounted Installation

Send your message to this supplier
Send Now

Digital Display Home Heating Boilers , Gas Fired Hot Water Boiler Wall Mounted Installation

Ask Latest Price
Brand Name :
Dongyuan
Model Number :
L1PB26-NC
Certification :
ISO14001,ISO9001,OHSAS18001
Place of Origin :
China,Shunde
MOQ :
Negotiable
Price :
Negotiable
Contact Supplier
Digital Display Home Heating Boilers , Gas Fired Hot Water Boiler Wall Mounted Installation
Digital Display Home Heating Boilers , Gas Fired Hot Water Boiler Wall Mounted Installation

Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.

Verified Supplier
7 Years
guangdong, foshan
Since 2007
Business Type :
Manufacturer, Trading Company
Total Annual :
5000000-100000000
Employee Number :
250~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement