Specifications
Brand Name :
Dongyuan
Model Number :
L1PB32-NK
Certification :
ISO14001,ISO9001,OHSAS18001
Place of Origin :
China,Shunde
MOQ :
Negotiable
Price :
Neogoitable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
10000pcs per month
Delivery Time :
30days after receiving the deposit
Packaging Details :
Each product in plastic bag which comes with the product instructions and foam packaging, then carton packaging outside with another thicker plastic bag.
Installation :
Wall Hung
Origin :
China
Burning Style :
Radiator
Pressure :
Low Pressure
Structure :
Water Tube
Fuel :
Natural Gas
Description

Gas Central Heating LCD Display For Room Heating And Sanitary Hot Water Home Gas Boiler

Technical data

Model Number L1PB24 L1PB32
Gas Type NG/LPG
Rated Gas Pressure(Pa) 2000/2800
Rated Gas Input(kw) 24 32
Rated Gas Output(kw) 21.1 28.2
Efficiency Under Rated Heat Input(%) Above88%
Power Supply 20-50HZ
Electric Power(W) 110 145
Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60
Heating Area(㎡) 100-200 200-300
Lift Of pump(m) 5 7
Application Water Pressure(Mpa) 0.1-0.3
Expansion Tank Capacity(L) 6 8
Preset Pressure Of Expansion Vessel(Mpa) 0.1
Water Circulation Type Airtight Forced Circulation
△T=25℃ Hot Water Supply(kg/min) 12 16
△T=30℃ Hot Water Supply(kg/min) 10 13.3
Temp.Range Of DHW Supply(℃) 30-60
Applicative Water Pressure(mpa) 0.03-0.8
The Minimum Starting Flow (L/min) 2
The Minimum Closed Flow(L/min) 1.6
Connections(mm) For Gas&Heating Water Pipes:G3/4 For DHW Pipes:G1/2
Air Input/Exhaust Duct(mm) φ60/φ100
Sparated Input/Exhaust Duct(optional) φ80/φ100
The length Of Flue Dust(m) 1
Noise On Working(DB) <42
Exhaust Type Forced Exhaust
Ignition Type Integrated Automatic Ignition
Temperature Control Gas Proportional Adjustment
Product Dimensions(mm) 740*400*305 855*470*390
Packing Dimensions(mm) 865*470*385 870*495*390
Container(20GP/40GP/40HQ) 17//357/434 166/333/404

- With control circuit boards,control centers for high- intelligent equipment opeartion and safety protection.

- With multi-stage intelligent antifreeze,multi-stage combustion, the temperature is less than 8 degrees celsius

to start automatically, the pump after sycle in th burning to stop working, the pump.

- Delay opeartion to prevent overheating repeatedly.

- With LED- all round electronic display.

- The original modular design, assembly and disassembly is simple, fault memory function, convenient for the

rapid diagnosis of after sales personnel.

- The invention patent high-frequency electronic anti scalling device and the original windbreak and sand

structure design are committed to manufacturing gas wall hanging stove products suitable for our conditions.

- Dynamic fire display, automatic central control data output, intuitive and convenient.

- Touch buttons, big-screen dynamic LCD display, sensitive and comfortable.

- Digital precise temperature control system, are free to adjust temperature.

- Green environmental protection,ultra-low emission.

- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation

process begin earlier and by higher return line temperature(about 57℃)

- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the

gas-air mix.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with

great optimization of gas consumption.

- Indication of temperatures, working modes, current burner power and error codes on the color multifunctional

LCD display.

- PCB is insensitive to the electric polarity and fluctuations of voltage AC 160-242 Volt.

- Integrated 24-hour/week timer sets normal or lower heating temperature within each day of week with the benefits

of comfort and low gas consumption.

- Automatic electronic ignition and ionization flame control.

- Can connect with room thermostat and remote controller which can provide more function options.

- Working mode and error codes indication by 1 light- emitting diodes(LCD) on the control panel.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with great

optimization of gas consumption.

- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use antifreeze

liquid instead of water in the heating system.

- Supports outdoor temperature driven mode.

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Send your message to this supplier
Send Now

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Ask Latest Price
Brand Name :
Dongyuan
Model Number :
L1PB32-NK
Certification :
ISO14001,ISO9001,OHSAS18001
Place of Origin :
China,Shunde
MOQ :
Negotiable
Price :
Neogoitable
Contact Supplier
Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display
Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.

Verified Supplier
7 Years
guangdong, foshan
Since 2007
Business Type :
Manufacturer, Trading Company
Total Annual :
5000000-100000000
Employee Number :
250~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement