18K 50hz 220V R22 Wifi Control Air Conditioner 18000BTU Only Cooling
VA Panel 50hz 220V R22 On-Off 18000BTU Only Coooling High Quality AC Units Mounted Cabinet Air Cooling 3years Warranty
Dehumidification
The air conditioner is accompanied by dehumidification during the refrigeration process. The relative humidity of the environment that people feel comfortable should be around 40-60%. When the relative humidity is too high, such as above 90%, even if the temperature is within a comfortable range, people still feel bad.
Purifying air
The air contains a certain amount of harmful gases such as NH3, SO2, etc., as well as various odors such as sweat, body odor and bathroom odor.
Purification methods for air conditioners include: changing fresh air, filtering, and using activated carbon or photocatalyst to absorb and absorb.
Item | Product | 18K | |||
Cool/Hea | Heat Pump | ||||
Climat | T1 | ||||
Powe | 220-240V/50HZ/1P | ||||
Type | On/Off | ||||
General | Cooling |
Rated Capacity | Btu/h / W | 2350 | |
Power Input | W | 959 | |||
Rated Current | A | 4.36 | |||
Rated EER | W/W | 2.45 | |||
Heating |
Rated Capacity | Btu/h / W | 2150 | ||
Power Input | W | 843 | |||
Rated Current | A | 3.83 | |||
Rated EER | W/W | 2.55 | |||
Rated Engery Star Rating | / | / | |||
Moisture removal | L/h | 0.4 | |||
Max Input Consumption | W | 1155 | |||
Max current | A | 6.14 | |||
Refrigerant Type/ Charge | g | R410A/* | |||
Air Flow Volume (Hi/Mi/Lo) | m3/h | 600 | |||
Indoor Noise level (Hi/Mi/Lo) | dB(A) | 22-24-39dB(A) | |||
Outdoor Noise level | dB(A) | 49dB(A) | |||
Indoor system | Indoor fan motor |
Model | RPG10C | ||
Input | W | 10W | |||
Capacitor | uF | 1.2uf | |||
Speed(Hi/Mi/Lo) | r/min | PG | |||
Indoor coil |
a.Number of rows | 1 | |||
b.Tube pitch(a)x row pitch(b) | mm | 25x18.19 | |||
c.Fin spacing | mm | 1.35 | |||
d.Fin type (code) | |||||
e.Tube outside dia.and type | mm | Φ7.94, | |||
Outdoor system | Outdoor fan motor |
Model | YDK24-6N3/YDK30-6Q6 | ||
Input | W | 30 | |||
Capacitor | uF | 2.5uf | |||
Speed(Hi/Mi/Lo) | r/min | 850 | |||
Outdoor coil |
a.Number of rows | 1 | |||
b.Tube pitch(a)x row pitch(b) | mm | 25*14 | |||
c.Fin spacing | mm | 1.35 | |||
d.Fin type (code) | |||||
e.Tube outside dia.and type | mm | Φ7.94, | |||
Function | Compressor |
Model | QXA-B098C130A | ||
Type | R410A | ||||
Brand | |||||
Refrigerant piping Size |
Material Type | ||||
Liquid Pipe | φmm (inch) | φ6 | |||
Gas Pipe | φmm (inch) | φ9 | |||
Max. refrigerant pipe length | m | 15 | |||
Max. difference in height | m | 5 | |||
Power Cord length | 1.7m | ||||
Plug type | |||||
Thermostat type | Remote | ||||
Operation temperature | ℃ | 16~31 | |||
Room temperature |
Indoor(cooling/ heating) | ℃ | -5~45/---- | ||
Outdoor(cooling/heating) | ℃ | 16~31/---- | |||
Application area (Cooling Standard) | m2 | 8-12 | |||
Features | Display on Front Panel | ||||
LCD Wireless Remote Controller | Yes | ||||
Removable and washable Panel | Yes | ||||
Healthy Filter -PHOTOCATALYTIC FILTER -ACTIVE CARBON FILTER -SILVER ION FILTER -CATECHIN FILTER |
/ | ||||
24 Hours Timer 24 | Yes | ||||
3 Speed and Auto Indoor Fan Control | Yes | ||||
Vertical Auto Swing Louver | Yes | ||||
Horizontal Auto Swing Louver | NO | ||||
Sleep Operation | Yes | ||||
Super Function | NO | ||||
Compressor Indicator | NO | ||||
Auto Restart | Yes | ||||
Golden Fins | NO | ||||
Others | Unit Dimensions WxHxD | Indoor Unit | mm | 880*299*202 | |
Outdoor Unit | mm | 600*240*435 | |||
Packing Dimensions WxHxD | Indoor Unit | ||||
mm | 710*340*500 | ||||
Net Weight | Indoor Unit | kg | 7.5 | ||
Outdoor Unit | kg | 23 | |||
Gross Weight | Indoor Unit | kg | 9.5 | ||
Outdoor Unit | kg | 26 | |||
Container QTY 20’ /40'HQ | 128/320 | ||||
Approval |
Maintenance
Maintenance before starting up
Generally, household air conditioners are turned off in September and then turned on from May to June of the following year. They will not be used for more than half a year. Therefore, a comprehensive "diagnosis" must be done before the air conditioner is turned on to check whether the air conditioner is "faulty". According to the results of the inventory, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning. This time, the maintenance and cleaning should be more in place. Including the casing, body, and filter of the outdoor unit and the indoor unit, and then start trial operation to observe the cooling speed and effect.
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part