CA Panel 12000BTU Outdoor Air Conditioner 220V50HZ R22 Split Type
CA Panel 220V50HZ R22 12000BTU Split Air Conditioning CoolingOnly High Quality Wifi Control PCB 3 Year Warranty
- Doors and windows of the room should not be opened and closed frequently, and personnel should not enter and exit frequently to avoid loss of air-conditioning;
- The glass windows must be closed and tightly closed, and double white curtains must be hung inside to reflect part of the light and heat that penetrates;
- The window can be opened for a short time during indoor ventilation, and the window opening time is generally no more than 10 minutes
- The air filter should be cleaned regularly, otherwise the air flow will be blocked, resulting in insufficient air volume and increased room temperature
- To adjust the temperature during sleep, the air conditioner can automatically adjust the sleep temperature
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
12000BTU | |||
Model No. | TAC-12CS/Z | ||
KF-35GW | |||
indoor 820(Φ7×2)+outdoor 780(Φ7.94×1) | |||
Type | cooling only | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 11535;3381 | |
Rated heating capacity | Btu/h;W | N.A | |
EER for cooling | Btu/h.w; W/W | 2.7 | |
COP for heating | W/W | N.A | |
Moisture removal | Liters/h | 1.3 | |
Pressure | High(DP) | MPa | 2.6 |
Low(SP) | MPa | 1 | |
Indoor noise level at cooling | High | dB(A) | 41 |
Med. | dB(A) | 37 | |
Low | dB(A) | 24 | |
Outdoor noise level | dB(A) | 52 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 5.8 |
Heating | A | N.A | |
Rated input | Cooling | W | 1253 |
Heating | W | N.A | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 9.8 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1790 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R22 | |
Compressor | Type | Rotary | |
Model | C-RV212H92CB/QX-B217E030A | ||
LRA | A | / | |
MFG | SANYO/GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 530 | |
Indoor fan type | Cross Flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1290/1150/900 |
Heating | rpm | N.A | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 13 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ12 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 1.0*3 | |
Drainage Pipe | |||
Suitable area | m2 | 12~23 | |
Net dimensions (W x H x D) | Indoor | mm | 820x250x205 |
Outdoor | mm | 780x540x255 | |
Net weight | Indoor | kg | 10 |
Outdoor | kg | 31 | |
Packing dimensions (W x H x D) | Indoor | mm | 880*315*269 |
Outdoor | mm | 870*340*590 | |
Gross weight | Indoor | kg | 11 |
Outdoor | kg | 33 |
Generally, household air conditioners are turned off in September and then turned on from May to June of the following year. They will not be used for more than half a year. Therefore, a comprehensive "diagnosis" must be done before the air conditioner is turned on to check whether the air conditioner is "faulty". According to the results of the inventory, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning. This time, the maintenance and cleaning should be more in place. Including the casing, body, and filter of the outdoor unit and the indoor unit, and then start trial operation to observe the cooling speed and effect.
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part