220V 50HZ R22 9000BTU Split Type Wall Mounted Ac Unit For Garage
CA Panel 220V50HZ R22 9000BTU Split Type Air Conditioning Cooling Heating High Quality Wifi Control PCB 3 Year Warranty
Precautions:
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;
9000BTU | |||
Model No. | YTA-09C | ||
KF-25GW | |||
indoor 770(Φ7.94×1)+outdoor700(Φ7.94×1) | |||
Type | cooling only | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 8048;2359 | |
Rated heating capacity | Btu/h;W | N.A | |
EER for cooling | Btu/h.w; W/W | 2.48 | |
COP for heating | W/W | N.A | |
Moisture removal | Liters/h | 0.78 | |
Pressure | High(DP) | MPa | 2.8 |
Low(SP) | MPa | 1.2 | |
Indoor noise level at cooling | High | dB(A) | 39 |
Med. | dB(A) | 34 | |
Low | dB(A) | 22 | |
Outdoor noise level | dB(A) | 49 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 4.4 |
Heating | A | N.A | |
Rated input | Cooling | W | 947 |
Heating | W | N.A | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 7.09 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1337 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R22 | |
Compressor | Type | Rotary | |
Model | 凌达QX-B160C130 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 430 | |
Indoor fan type | Cross Flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1160/1060/900 |
Heating | rpm | N.A | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 8 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ9 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*0.75 | |
Drainage Pipe | |||
Suitable area | m2 | 8~12 | |
Net dimensions (W x H x D) | Indoor | mm | 770x250x205 |
Outdoor | mm | 700x540x255 | |
Net weight | Indoor | kg | 8.5 |
Outdoor | kg | 28 | |
Packing dimensions (W x H x D) | Indoor | mm | 830*268*316 |
Outdoor | mm | 805*340*590 | |
Gross weight | Indoor | kg | 9.5 |
Outdoor | kg | 30 |
Maintenance
Maintenance before starting up
Generally, household air conditioners are turned off in September and then turned on from May to June of the following year. They will not be used for more than half a year. Therefore, a comprehensive "diagnosis" must be done before the air conditioner is turned on to check whether the air conditioner is "faulty". According to the results of the inventory, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning. This time, the maintenance and cleaning should be more in place. Including the casing, body, and filter of the outdoor unit and the indoor unit, and then start trial operation to observe the cooling speed and effect.