R22 50hz 220V Cooling Air Conditioner Wall Mount 12000 BTU OEM
VA Panel 50hz 220V R22 On-Off 12000BTU Only Coooling High Quality AC Units Mounted Cabinet Air Cooling
Maintenance
Maintenance before starting up
Generally, household air conditioners are turned off in September and then turned on from May to June of the following year. They will not be used for more than half a year. Therefore, a comprehensive "diagnosis" must be done before the air conditioner is turned on to check whether the air conditioner is "faulty". According to the results of the inventory, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning. This time, the maintenance and cleaning should be more in place. Including the casing, body, and filter of the outdoor unit and the indoor unit, and then start trial operation to observe the cooling speed and effect.
Item | Product | 9K | |||
Cool/Hea | Heat Pump | ||||
Climat | T1 | ||||
Powe | 220-240V/50HZ/1P | ||||
Type | On/Off | ||||
General | Cooling |
Rated Capacity | Btu/h / W | 2350 | |
Power Input | W | 959 | |||
Rated Current | A | 4.36 | |||
Rated EER | W/W | 2.45 | |||
Heating |
Rated Capacity | Btu/h / W | 2150 | ||
Power Input | W | 843 | |||
Rated Current | A | 3.83 | |||
Rated EER | W/W | 2.55 | |||
Rated Engery Star Rating | / | / | |||
Moisture removal | L/h | 0.4 | |||
Max Input Consumption | W | 1155 | |||
Max current | A | 6.14 | |||
Refrigerant Type/ Charge | g | R410A/* | |||
Air Flow Volume (Hi/Mi/Lo) | m3/h | 600 | |||
Indoor Noise level (Hi/Mi/Lo) | dB(A) | 22-24-39dB(A) | |||
Outdoor Noise level | dB(A) | 49dB(A) | |||
Indoor system | Indoor fan motor |
Model | RPG10C | ||
Input | W | 10W | |||
Capacitor | uF | 1.2uf | |||
Speed(Hi/Mi/Lo) | r/min | PG | |||
Indoor coil |
a.Number of rows | 1 | |||
b.Tube pitch(a)x row pitch(b) | mm | 25x18.19 | |||
c.Fin spacing | mm | 1.35 | |||
d.Fin type (code) | |||||
e.Tube outside dia.and type | mm | Φ7.94, | |||
Outdoor system | Outdoor fan motor |
Model | YDK24-6N3/YDK30-6Q6 | ||
Input | W | 30 | |||
Capacitor | uF | 2.5uf | |||
Speed(Hi/Mi/Lo) | r/min | 850 | |||
Outdoor coil |
a.Number of rows | 1 | |||
b.Tube pitch(a)x row pitch(b) | mm | 25*14 | |||
c.Fin spacing | mm | 1.35 | |||
d.Fin type (code) | |||||
e.Tube outside dia.and type | mm | Φ7.94, | |||
Function | Compressor |
Model | QXA-B098C130A | ||
Type | R410A | ||||
Brand | |||||
Refrigerant piping Size |
Material Type | ||||
Liquid Pipe | φmm (inch) | φ6 | |||
Gas Pipe | φmm (inch) | φ9 | |||
Max. refrigerant pipe length | m | 15 | |||
Max. difference in height | m | 5 | |||
Power Cord length | 1.7m | ||||
Plug type | |||||
Thermostat type | Remote | ||||
Operation temperature | ℃ | 16~31 | |||
Room temperature |
Indoor(cooling/ heating) | ℃ | -5~45/---- | ||
Outdoor(cooling/heating) | ℃ | 16~31/---- | |||
Application area (Cooling Standard) | m2 | 8-12 | |||
Features | Display on Front Panel | ||||
LCD Wireless Remote Controller | Yes | ||||
Removable and washable Panel | Yes | ||||
Healthy Filter -PHOTOCATALYTIC FILTER -ACTIVE CARBON FILTER -SILVER ION FILTER -CATECHIN FILTER |
/ | ||||
24 Hours Timer 24 | Yes | ||||
3 Speed and Auto Indoor Fan Control | Yes | ||||
Vertical Auto Swing Louver | Yes | ||||
Horizontal Auto Swing Louver | NO | ||||
Sleep Operation | Yes | ||||
Super Function | NO | ||||
Compressor Indicator | NO | ||||
Auto Restart | Yes | ||||
Golden Fins | NO | ||||
Others | Unit Dimensions WxHxD | Indoor Unit | mm | 880*299*202 | |
Outdoor Unit | mm | 600*240*435 | |||
Packing Dimensions WxHxD | Indoor Unit | ||||
mm | 710*340*500 | ||||
Net Weight | Indoor Unit | kg | 7.5 | ||
Outdoor Unit | kg | 23 | |||
Gross Weight | Indoor Unit | kg | 9.5 | ||
Outdoor Unit | kg | 26 | |||
Container QTY 20’ /40'HQ | 128/320 | ||||
Approval |
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part
Precautions
- The indoor temperature cannot be adjusted too low, otherwise it is harmful to the human body, so the set temperature should be adjusted appropriately.
- If you feel the room temperature is too high, you can appropriately lower the set temperature.
Effective use of timers can achieve both energy-saving and comfortable effects.
- There should not be too many people or overcrowding in the air-conditioned room, otherwise the cooling capacity will be insufficient and the temperature will not drop;