BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof Type



Specification

Performance Features

◆ The controller enclosure is flameproof type, reliable explosion-proof performance.

◆ Static grounding clamp has tank car identification function, ensure its installed on tank car correctly, not other electric conductor, with no-spark type grounding clamp, no spark produced when equipment impact.

◆ Static grounding clamp has resistance inspection and liquid level monitoring function, provide local and remote audible and visual alarm and interlocking signal for “static” and ''overflow status”, which is convenient for operator to find out problem and avoid overflow accident.

◆ Grounding body resistance has inspection function, ensure reliable grounding of system, when electrostatic grounding is bad or grounding loop resistance >10Ω, provide alarm warning.

◆ With voice and LCD function, the intensity of the sound is 70~120db (the distance is 30cm).

◆ Relay signal output for DCS pump (valve), when grounding is not normal, cut off the operation, audible and visual alarm can still be remote controlled, remind operator the real-time status of on-site grounding.

◆ Red LED shows warning, green LED shows normal working, yellow LED shows standby status.

◆ Grounding clamp uses alloy aiding thimble, with the features of high hardness, good electric conduction, strong breaking paint and rust power, etc. ensure good grounding monitoring device.

◆ Grounding clamp is helix tube shrink design, with the capacities of strength anti-pull, anti-drop, etc.

◆ It can intelligently detect whether the human static voltage is conducted, when the human static voltage is in a dangerous value,sound and light alarm.



Data
Type spec. and name Parameters Remark

BXCQ-YJC

Explosion-proof Overflow Static Grounding Controller

Ex mark:II 2 G Ex db ia IIB+H2 T6 Gb

II 2 D Ex ia tb IIIC T80℃ Db

Protection degree: IP66

Response time: <1S

Test resistance: <10Ω

Working voltage: 100~250V AC 50/60HZ,
220V~240V AC 50/60Hz, 24V DC

Working current: <20mA

Warning method: Interlocking signal and three

color light instruction

Output signal: Relay output, NO NC is optional,

10A 30VDC or 10A 250VAC

Enclosure size: 200x300x170 mm

Installation dimension: 210x230 mm

Aluminium

alloy

enclosure

BXCQ-JC

Explosion-proof StaticGrounding Controller

Ex mark: II 2 G Ex db ia IIB+H2 T6 Gb

II 2 D Ex ia tb IIIC T80℃ Db IP66

Protection degree: IP66

Response time: <1S

Test resistance: <10Ω

Working voltage: 100~250V AC 50/60HZ,
220V~240V AC 50/60Hz, 24V DC

Working current: <20mA

Warning method: sound and light alarm (optional)

Output signal: Relay output, NO NC is optional,

10A 30VDC or 10A 250VAC

Enclosure size: 200x300x170 mm

Installation dimension: 210x230 mm

Aluminium

alloy

enclosure

BXCQ-YC

Explosion-proof Overflow Controller

Ex mark: II 2 G Ex db ia IIB+H2 T6 Gb

II 2 D Ex tb IIIC T80℃ Db IP66

Protection degree: IP66

Response time: <1S

Working voltage: 100~250V AC 50/60HZ,
220V~240V AC 50/60Hz, 24V DC

Working current: <20mA

Warning method: Interlocking signal and three

color light instruction

Output signal: Relay output, NO NC is optional

10A 30VDC or 10A 250VAC

Enclosure size: 200x300x170 mm

Installation dimension: 210x230 mm

Aluminium

alloy

enclosure

BXCQ-JCL

Explosion-proof Static

Grounding Controller

(dual purposes of manand motor)

Ex mark:II 2 G Ex db ia IIB T6 Gb

II 2 D Ex ia tb IIIC T80℃ Db IP66

Protection degree: IP66

Response time: <1S

Test resistance: <10Ω

Working voltage: 220VAC or 24VDC

Working current: <20mA

Warning method: sound and light alarm (optional)

Output signal: Relay output, NO NC is optional,

10A 30VDC or 10A 250VAC

Touching ball material: Electrostatic subconductor

Touching ball diameter: 90mm

Enclosure size: 200x300x170 mm

Installation dimension: 210x230 mm

Aluminium

alloy

enclosure

BXJ-IIB

Series Explosion-proof

Junction Box

Ex mark:II 2 G Ex db IIB+H2 T6 Gb

II 2 D Ex tb IIIC T80℃ Db IP66

Protection degree: IP66

Aluminium

alloy

enclosure

Static Grounding Clamp

Clamp tooth material: Tungsten alloy

Opening range:Clamp body material: 304 (316 optional)


Corrosion Resistance

Helical Line

Cable material: Copper wire

Surface material: PU

Standard equipment length: 7m

The length

of helical

Line is

customized,

the max

length is 15m

Homing board Material: 304 stainless steel


Download


BXCQ Explosion-proof Overflow Static Grounding Control System

(Download here:BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof TypeBXCQ Explosion-proof Overflow Static Grounding Control System.pdf)



Contact us for more information:

Address : No. 555, Baoqian Road, Jiading District, Shanghai, China

Zip Code: 201808

Tel: +86 21 39977076 /+86 21 39972657

Fax: +86 21 39977077

E-mail: gmb@warom.com





Send your message to this supplier
Send Now

BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof Type

Ask Latest Price
Brand Name :
Warom
Model Number :
BXCQ
Place of Origin :
China
Payment Terms :
T/T
Packaging Details :
carton packing/wooden box package
Explosive Gas Atmosphere :
Zone 1,Zone 2,IIA,IIB
Contact Supplier
BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof Type

Warom Technology Incorporated Company

Verified Supplier
1 Years
shanghai, shanghai
Since 1987
Business Type :
Manufacturer, Seller
Total Annual :
1000000-2000000
Employee Number :
2000~2300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement