JLSF-25HP Air Cooled Water Chiller Space-Saving And Durable For Research Facilities
Product Description:
The laboratory air-cooled chiller is a kind of equipment specially designed to provide refrigeration services for laboratories and scientific research institutions. It is basically designed by combining the working principle of the air-cooled chiller with the requirements of the laboratory.
Air-cooled chiller is a kind of chiller equipment, also known as chiller. It discharges heat by using an air condenser, so it is called "air-cooled", which is different from the way water-cooled chillers work, which uses a water condenser to discharge heat.
Compared with the traditional water-cooled chiller, the difference between the air-cooled chiller and the traditional water-cooled chiller is that it uses an air cooler as a condenser, and the fan blows the air required for heat dissipation from one side of the machine and exhausts it from the other side. Achieve cooling. Therefore, the air-cooled chiller does not need an external cooling water source, is independent, and is very convenient to install and move.
Product Features:
The air-cooled chiller for research institutions is a high-performance cooling device with the following features and descriptions:
1. Wide temperature control range: This air-cooled chiller can provide a wide temperature control range, including normal temperature, low temperature and high temperature. It can accurately control the temperature according to experimental needs and provide stable temperature output.
2. High-precision temperature control: This chiller has high-precision temperature control capabilities, usually within a range of ±0.1°C, to meet the experimental accuracy requirements of research institutions.
3. Multi-functional working mode: This chiller has multiple working modes, including constant temperature cycle, low temperature cycle and high temperature cycle. It can switch different working modes according to experimental needs and adapt to different experimental requirements and application scenarios.
4. Adjustable power and flow control: The chiller has adjustable power and flow control functions, which can be flexibly adjusted according to experimental needs to meet the cooling capacity requirements of different experiments.
5. Silent operation: This chiller adopts a low-noise design to ensure a low noise level during operation. This is very important for research institutions that require a quiet experimental environment.
6. Energy-saving and efficient: The chiller adopts an energy-saving and efficient design, with an optimized energy management system and intelligent operation control. It can reduce energy consumption, improve operating efficiency, and reduce operating costs.
7. Easy to operate and maintain: The chiller has a user-friendly operating interface and control system, allowing users to easily set and monitor temperature parameters. In addition, it is designed for easy maintenance and service to reduce equipment maintenance and downtime.
8. Safety protection function: The chiller has multiple safety protection functions, including over-temperature protection, over-current protection and leakage protection. These security features ensure the safety of the laboratory environment and users.
The air-cooled chiller described above is a high-performance cooling equipment suitable for research institutions, capable of meeting complex experimental needs and providing stable temperature control. When choosing, you can choose the appropriate model and specifications based on specific experimental requirements and budget constraints.
Techinical Parameters:
Model | JLSF-1HP | JLSF-2HP | JLSF-3HP | JLSF-4HP | JLSF-5HP | JLSF-6HP | JLSF-8HP | JLSF-10HP | ||
Cooling capacity | KW/h | 3.1 | 6.2 | 9.3 | 12.4 | 15.5 | 18.6 | 24.8 | 31 | |
Kcal/h | 2,700 | 5,400 | 8,100 | 10,800 | 13,500 | 16,200 | 21,600 | 27,000 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 1.21 | 2.03 | 2.84 | 3.7 | 4.5 | 5.7 | 7.33 | 8.83 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 0.75 | 1.50 | 2.25 | 3.00 | 3.75 | 4.50 | 6.00 | 7.50 | |
Circulating pump | Power | KW | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 | 1.5 |
Head | m | 22 | 22 | 22 | 22 | 23 | 23 | 23 | 21.5 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 0.50 | 1.00 | 1.50 | 2.00 | 2.50 | 3.00 | 4.00 | 5.00 | |
Evaporator | Flow | m³/h | 0.82 | 0.98 | 1.45 | 1.88 | 2.42 | 2.92 | 3.75 | 4.85 |
water capacity | m³ | 0.028 | 0.04 | 0.05 | 0.05 | 0.065 | 0.065 | 0.13 | 0.18 | |
Diameter | inch | 1/2" | 3/4" | 1" | 1-1/2" | 1-1/2" | ||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 680 | 800 | 1040 | 1140 | 1140 | 1200 | 1400 | 1400 |
W | mm | 420 | 480 | 555 | 620 | 620 | 650 | 725 | 725 | |
H | mm | 720 | 850 | 1060 | 1200 | 1200 | 1160 | 1450 | 1450 | |
Unit weight | Kg | 60 | 90 | 130 | 140 | 170 | 210 | 270 | 350 |
Model | JLSF-12HP | JLSF-15HP | JLSF-20HP | JLSF-25HP | JLSF-30HP | JLSF-40HP | JLSF-50HP | JLSF-60HP | ||
Cooling capacity | KW/h | 37.2 | 46.5 | 65 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 29,059 | 37,965 | 50,805 | 61,683 | 74,992 | 97,675 | 116,521 | 156,249 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 11.4 | 13.62 | 19.8 | 22.75 | 28.3 | 39.2 | 46.75 | 56.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | 45 | |
Circulating pump | Power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 5.5 |
Head | m | 21.5 | 21.5 | 22 | 22 | 25 | 25 | 25 | 26 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 7.2 | 9.1 | 12.2 | 15.3 | 18.6 | 24.5 | 30.6 | 36.8 | |
Evaporator | Flow | m³/h | 5.81 | 7.6 | 10.16 | 12.34 | 15.2 | 19.53 | 23.3 | 30.52 |
water capacity | m³/h | 0.18 | 0.21 | 0.28 | 0.32 | 0.32 | 0.61 | 0.66 | 0.72 | |
Diameter | inch | 1.5" | 2" | 2.5" | 3" | |||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 1400 | 1750 | 2000 | 2000 | 2200 | 2000 | 2000 | 2400 |
W | mm | 725 | 750 | 900 | 900 | 900 | 1800 | 1800 | 1800 | |
H | mm | 1450 | 1500 | 1770 | 1770 | 1770 | 2200 | 2300 | 2300 | |
Unit weight | Kg | 370 | 480 | 590 | 590 | 880 | 1000 | 1280 | 1420 |
Application Industry:
Small air-cooled chillers are suitable for many different industries and applications, including but not limited to the following:
1.Electronics industry: Small air-cooled chillers can provide refrigeration for high-tech products such as semiconductors, optics, and electronic components to ensure the normal operation of the equipment.
2.Pharmaceutical industry: small air-cooled chillers can provide stable cooling effect for the link in the pharmaceutical production process that requires temperature control, ensuring the quality and safety of pharmaceuticals.
3.Food industry: Small air-cooled chillers can provide refrigeration for the links that require temperature control during food processing, storage and transportation to ensure the quality and safety of food.
4.Plastic industry: small air-cooled chillers can provide refrigeration for the temperature-controlled links in plastic injection molding, blow molding, extrusion molding, etc., to ensure product quality and production efficiency.
5.Chemical industry: small air-cooled chillers can provide refrigeration for the links that need temperature control in the chemical production process to ensure the quality and safety of chemical products.
In general, small air-cooled chillers are suitable for various occasions that require refrigeration, and provide efficient, stable and reliable refrigeration solutions for different industries.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Product Maintenance:
For the maintenance of air-cooled chillers, the following are some important considerations:
1. Clean the filter regularly: Air-cooled chillers are often equipped with air filters to prevent dust and impurities from entering the system. Regular filter cleaning is key to keeping your equipment running properly. Depending on the frequency of use and environmental conditions, it is recommended to check the filter and clean or replace it every once in a while.
2. Check the coolant level: Check the coolant level of the chiller regularly to ensure it is within the appropriate level range. If the fluid level is too low, appropriate coolant should be added in time. At the same time, check the quality and concentration of the coolant to ensure that it meets the requirements.
3. Clean the condenser and cooling fan: The condenser and cooling fan are key components of the air-cooled chiller and are responsible for heat dissipation. Regularly check and clean the condenser and cooling fan to prevent dust and dirt from clogging it and causing poor heat dissipation. Dust accumulation can be gently removed using a blower or brush.
4. Check the pipes and joints: Check the pipes and joints of the chiller regularly to make sure there are no leaks or looseness. If any problems are found, damaged parts should be repaired or replaced promptly.
5. Check electrical connections: Check your chiller's electrical connections regularly to make sure wires and plugs are not frayed or loose. Make sure all electrical components are working properly and comply with safety standards.
6. Periodic maintenance: Perform periodic maintenance procedures according to the maintenance manual or guide provided by the chiller supplier. This may include replacing seals, lubricating components, calibrating temperature control systems, etc. Follow your supplier's maintenance recommendations to ensure chiller performance and reliability.
7. Follow safe operating procedures: Always follow safe operating procedures when operating and maintaining your chiller. Make sure the equipment is in correct working order and follow all safety instructions and warnings.
Regular maintenance can ensure the normal operation of the air-cooled chiller, extend the life of the equipment, and provide reliable cooling effect. Note that specific maintenance requirements may vary by chiller model and manufacturer, so it's best to refer to the equipment's owner's manual or consult your supplier for detailed maintenance guidelines.