JLSW-200D Water Cooled Screw Chiller Bottled Beverage Production, Beverage Filling Machines, Ice Machines
Product Description:
Chillers are widely used in the beverage industry, mainly for refrigeration, cooling and heat preservation. The following are some applications of chillers in the beverage industry:
1.Refrigeration: Chillers can provide cooling water for refrigeration equipment for refrigeration, refrigeration and preservation. In the beverage industry, chillers are often used in refrigeration equipment, such as refrigeration systems for beverage machines, freezers, and cold drink machines.
2.Cooling: The chiller can provide cooling water for the production equipment in the beverage production line, such as beverage filling machines, coolers, etc. Through the circulating flow of cooling water, the heat generated in the equipment can be quickly dissipated to ensure the normal operation of the equipment.
3.Heat preservation: The chiller can provide hot water for the production equipment in the beverage production line, such as heat preservation tanks, water heaters, etc. Through the circulating flow of hot water, the temperature inside the device can be kept stable to ensure the quality and taste of the beverage.
4.Bottle washing: In the beverage production line, bottles need to go through cleaning, disinfection and other processes. The chiller can provide cooling water and cleaning water for the bottle washing machine, ensuring that the bottles can be cooled and cleaned quickly.
In short, the chiller plays an important role in the beverage industry, which can provide the necessary water source for refrigeration, cooling, heat preservation and cleaning, etc., to ensure the normal operation and production efficiency of the beverage production line.
Production Features:
Water-cooled screw machine is a commonly used refrigeration equipment with the following characteristics:
1.High efficiency and energy saving: The water-cooled screw machine adopts twin-screw compressors, which has the characteristics of high efficiency and energy saving. Twin-screw compressors have higher refrigeration efficiency and lower energy consumption than traditional single-screw compressors.
2.Stable and reliable: The operation of the water-cooled screw machine is stable and reliable, and has the characteristics of long life. Its structure is simple, maintenance is convenient, and it can meet the needs of different users.
3.Controllable energy consumption: The water-cooled screw machine can control energy consumption according to actual needs, and realize precise control through the control system, so as to achieve the purpose of energy saving.
4.Environmental protection and energy saving: The water-cooled screw machine adopts environmentally friendly refrigerants, which have low greenhouse effect and zero ozone layer destruction potential, and meet environmental protection requirements.
5.Wide range of application: The water-cooled screw machine has a wide range of applications and can be widely used in air conditioning, cold storage, industrial refrigeration and other fields.
6.Low noise: The noise of the water-cooled screw machine is low, which can meet the needs of noise-sensitive occasions.
7.Strong flexibility: The installation and use of water-cooled screw machines are very flexible, and can be customized and installed according to different places and equipment requirements.
In short, the water-cooled screw machine has the advantages of high efficiency and energy saving, stability and reliability, controllable energy consumption, environmental protection and energy saving, wide application range, low noise, and strong flexibility. It can meet the needs of different users and is a very practical refrigeration equipment.
Working Principle:
The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.
2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.
3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.
4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.
Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.
Techinical Parameters:
Model | JLSW-30D | JLSW-40D | JLSW-50D | JLSW-60D | JLSW-80D | JLSW-100D | JLSW-120D | JLSW-150D | ||
Cooling capacity | KW/h | 100 | 140 | 180 | 200 | 260 | 370 | 430 | 550 | |
TR | 28.5 | 39.8 | 51.2 | 56.9 | 73.9 | 105.2 | 122.3 | 156.4 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 22 | 30 | 36 | 41 | 56 | 80 | 93 | 118 | |
electric current | A | 39 | 51 | 65 | 71 | 95 | 135 | 156 | 198 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 16.5 | 22.2 | 27.5 | 33.4 | 44.4 | 55.6 | 66.5 | 82.6 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 17.2 | 22.4 | 29.3 | 33 | 43.9 | 64.2 | 75.2 | 95.3 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 22.4 | 29.2 | 35.2 | 42.9 | 57.8 | 84.3 | 101.1 | 123.9 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 2200 | 2250 | 2350 | 2450 | 2500 | 2900 | 3000 | 3000 |
W | mm | 800 | 800 | 800 | 900 | 900 | 900 | 1500 | 1500 | |
H | mm | 1500 | 1600 | 1650 | 1750 | 1800 | 1850 | 1500 | 1550 | |
Unit weight | Kg | 960 | 990 | 1260 | 1380 | 1520 | 1830 | 2150 | 2580 |
Model | JLSW-170D | JLSW-200D | JLSW-230D | JLSW-260D | JLSW-280D | JLSW-310D | JLSW-350D | JLSW-400D | ||
Cooling capacity | KW/h | 620 | 710 | 830 | 930 | 1020 | 1130 | 1270 | 1530 | |
TR | 176.3 | 201.9 | 236 | 264.4 | 290 | 321.3 | 361.1 | 435 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 130 | 150 | 175 | 200 | 225 | 250 | 281 | 325 | |
electric current | A | 218 | 253 | 295 | 335 | 390 | 432 | 480 | 553 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 93.8 | 111.2 | 126.8 | 144.1 | 155.4 | 170.9 | 193.2 | 220.9 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 108.6 | 126.3 | 144.9 | 163.8 | 176.4 | 196.5 | 222.4 | 252.6 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 141.1 | 166.2 | 190.9 | 215.8 | 232.4 | 258.6 | 290.8 | 333.2 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 3600 | 3600 | 3600 | 3650 | 3650 | 3700 | 3700 | 4200 |
W | mm | 1500 | 1500 | 1500 | 1600 | 1650 | 1750 | 1750 | 1750 | |
H | mm | 1650 | 1650 | 1700 | 1700 | 1700 | 1750 | 1800 | 1800 | |
Unit weight | Kg | 3050 | 3200 | 3450 | 3780 | 4060 | 4330 | 4600 | 4820 |
Application Industry:
In the beverage machinery production line, there are many equipment that need to use chillers to provide cooling and refrigeration functions. The following are some commonly used beverage machinery and equipment that require a chiller:
1.Beverage machine: Beverage machines usually need refrigeration to keep the temperature of the beverage so that consumers can enjoy a cool taste. The chiller can provide chilled water for the beverage machine to control the temperature of the beverage.
2.Freezers: Freezers are also common beverage machinery and equipment, usually requiring refrigeration to keep ice cubes, ice cream, etc. cold. Chillers can provide chilled water for freezers to keep ice cubes, ice cream, etc. cold.
3.Bottled beverage production line: In the bottled beverage production line, beverages need to be cooled, refrigerated and kept warm. The chiller can provide low-temperature cooling water and high-temperature hot water to ensure that the temperature of beverages in the production line is stable.
4.Beverage filling machine: The beverage filling machine needs to cool, refrigerate and keep warm the beverage to ensure the quality of the beverage. The chiller can provide low-temperature cooling water and high-temperature hot water for the beverage filling machine to control the temperature of the beverage.
5.Ice maker: The ice maker needs to provide low-temperature ice-making water to make ice cubes, hockey balls and other ice products. The chiller can provide low-temperature ice-making water for the ice machine to ensure the quality of ice cubes, hockey pucks, etc.
In short, the chiller plays an important role in the beverage machinery production line. It can provide necessary water sources such as refrigeration, cooling, heat preservation and ice making to ensure the normal operation of the production line and the quality of beverages.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
How often should the heat exchanger be cleaned and the filter replaced?
The frequency of cleaning the heat exchanger and replacing the filter element depends on the usage and environmental conditions of the water-cooled screw chiller. It is generally recommended to clean and replace at the following frequency:
1.Cleaning the heat exchanger: It is recommended to clean the heat exchanger at least once a year. If the water quality is poor or the environment is dusty, it is recommended to increase the cleaning frequency to ensure the heat transfer efficiency and operation effect of the heat exchanger.
2.Replacing the filter element: It is generally recommended to replace the filter element every quarter. If the water quality is poor or the frequency of use is high, it is recommended to replace the filter element once a month. Replacing the filter element can effectively prevent scale, sand and other impurities from clogging the waterway and avoid affecting the normal operation of the chiller.
It should be noted that the cleaning and replacement operations need to be carried out by professionals to ensure correct, safe and effective operation. At the same time, regular maintenance can also prolong the service life of the water-cooled screw chiller and reduce maintenance and replacement costs.