Energy savings due to integrated electronic power adjustment
Optional interfaces for bus communication using plug-in IF-Modules
Simple operation due to tried-and-tested Green Button Technology and display
Integrated full motor protection (PTC thermistor sensor) with trip electronics
Meets user requirements thanks to performance and main dimensions in accordance with EN 733 (for end-suction pumps)
Use of IE4 motor technology and hydraulics with an MEI ≥ 0.4 saves energy
Sustainable and carbon-neutral production and processes in our European factorie
Electronically controlled glanded single pump in monobloc design with flange connection and automatic power adjustment.
The pumping of heating water (in accordance with VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, chilled water and cooling systems.
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID-Control
Constant speed (n=constant)
Manual operation level
Green button and display
Manual functions
Differential pressure setpoint setting
Setting the speed (manual control mode)
Setting the operating mode
Setting the pump ON/OFF
Configuration of all operating parameters
Fault acknowledgement
External control functions
"Overriding Off" control input
Analogue input 0 – 10 V, 0 – 20 mA for constant speed (DDC) and remote setpoint adjustment
Analogue input 2 – 10 V, 4 – 20 mA for constant speed (DDC) and remote setpoint adjustment
Analogue input 0 – 10 V for actual value signal from pressure sensor
Analogue input 2 – 10 V, 0 – 20 mA, 4 – 20 mA for actual value signal from pressure sensor
Signal and display functions
Collective fault signal SSM
Collective run signal SBM
Data exchange
Infrared interface for wireless data exchange with IR-Monitor/IR-Stick
Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Interface to twin-head pump communication
Safety functions
Full motor protection with integrated trip electronics
Access disable
Dual pump management (2 x single pump; Y-piece application only)
Main/standby operation (automatic fault-actuated switchover)
Pump cycling main/standby operation after 24 hours
Parallel operation
Parallel operation (efficiency-optimised peak load activation and deactivation)
Permissible temperature range of -20 °C to +140 °C
Minimum efficiency index (MEI) ≥ 0.4
Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
Mains connection
3~440 V -5% +10%, 50/60 Hz
3~400 V ±10%, 50/60 Hz
3~380 V -5% +10%, 50/60 Hz
Compliance with electromagnetic compatibility without additional measures:
Interference emission for residential environment according to EN 61800-3:2018
Interference immunity for industrial environments according to EN 61800-3:2018
Protection class IP55
Nominal diameter DN 32 to DN 150
Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C
Pump housing and lantern: Standard: EN-GJL-250
Impeller: Standard: EN-GJL-200; optional: Bronze CuSn 10, stainless steel 1.4408
Shaft: 1.4122
Mechanical seal: AQEGG other mechanical seals on request
Single-stage low-pressure centrifugal pump in monobloc design, with axial suction port and radially arranged discharge port with
Mechanical seal
Flange connection with pressure measuring connection R 1/8
Lantern
Coupling
Drive with integrated electronic speed control
Pump
Installation and operating instructions
Variant …-R1 without differential pressure sensor
...-L1 variant with bronze impeller (at additional charge)
…-L4 variant with stainless steel impeller (at additional charge)
Supporting blocks for installation on a base
IR-Monitor, Wilo-IR-Stick
IF module PLR for connecting to PLR/interface converter
IF module LON for connection to the LONWORKS mains network
IF module BACnet
IF module Modbus
IF module CAN
Control system VR-HVAC
Control system CCe-HVAC
Control system SCe-HVAC
Differential pressure sensor (DDG)