50W IP65 constant current led driver,waterproof 36V 1.3A led driver
Features
1. Constant current mode output
2. Metal housing with Class I design
3. Built in Active PFC design function
4. IP65 rating for indoor or outdoor installations
5. Function options:3 in 1 dimming,timmer dimming
6. 3 years warranty
Specifications
Model | ZF-BLB-50-36 | ZF-BLB-50W-48 | ZF-BLB-50-60 | ZF-BLB-50-72 | Customized | |||||
output | DC voltage | 27-36v | 36-48v | 48-60v | 60-72v | undetermined | ||||
Rated current | 1.8-1.4A | 1.4A-1.0A | 1.0-0.8A | 0.8-0.7A | undetermined | |||||
Rated power | 50W | 50W | 50W | 50W | 50W | |||||
Ripple current | 1000MA Max | 200MA Max | 200MA Max | 100MA Max | undetermined | |||||
voltage tolerance | ±3% | ±3% | ±3% | ±3% | ±3% | |||||
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
Load regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
Setup,rise time | 300ms,80ms/115VAC 300ms,80ms/230VAC | |||||||||
Hold up time | 16ms / 115VAC, 230VAC | |||||||||
Input | Input voltage | 90-277V | ||||||||
Frequency range | 47-63HZ | |||||||||
Power factory | PF≧0.99/100VAC, PF≧0.95/230VAC @ full load | |||||||||
Efficiency | 87% | 88% | 89% | 90% | undetermined | |||||
AC current | 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC | |||||||||
Inrush current | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||||
Leakage current | <0.75mA / 277VAC | |||||||||
Protection | Over current | Constant current limiting, recovers automatically after fault condition is removed | ||||||||
Short circuit | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
Over temperature | Shut down o/p voltage, re-power on to recover | |||||||||
Environment | Working Temp. | Tcase= -40 ~ +60℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) | ||||||||
Max.Case Temp. | Tcase= +80℃ | |||||||||
Working Humidity | 20 ~ 95% RH non-condensing | |||||||||
Temp.coefficient | ±0.03%/℃(0 ~ 60℃) | |||||||||
Vibration | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
Safty and standards | Safty standards | EN 61347-1:2008+A1:2011+A2:2013 ,EN 61347-2-13:2006, EN 62493:2010 | ||||||||
Isolaton resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:1.85KVAC O/P-FG:1.5KVAC | |||||||||
EMC emission | Compliance to EN55015, EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1 | |||||||||
EMC immunity | Compliance to EN61547:EN55042,EN61000-4-2,3,4,5,6,8,11,GB/T18595,Gb17626 | |||||||||
Others | MTBF | 1132K hrs min. Telcordia SR-332 (Bellcore) ; 338K hrs min. MIL-HDBK-217F (25℃) | ||||||||
Dimension | L150*W40*H30mm | |||||||||
Packing | 0.24kg/pcs 20pcs/4.8kg | |||||||||
Note | 1.All parameters not specially mentioned are measured at 230vAc input,rated current and 25℃of ambient temperature 2. ripple and noise measurement method using a 0.5 - mm twisted pair, and terminal capacitor in parallel with 0.1uF and 47uF, were measured in a 20MHZ bandwidth. 3. safety design of EN60598-1 and EMC, CNS15233, GB700.1, FCC, part18. 4. start time is measured in the cold start, switch frequently may make the starting time of change. 5. the power supply is considered as a component, which is used in conjunction with the terminal equipment. Because the EMC is affected by the whole set of equipment, the terminal equipment manufacturer needs to make a EMC confirmation of the whole set of devices 6. reference Warranty Statement |
Dimension