150W waterproof constant voltage led driver IP67 12V/24V led power supply
Features:
•Constant Voltage mode LED power supply.
•Universal AC input/full range 90-277VAC 50/60Hz..
•Withstand 3750VAC surge input for 5 seconds.
•Available for customizing output current/voltage.
•Protections: Short Circuit/Over Load/Over Voltage/Over Temperature.
•Cooling by free air convection.
•Fully encapsulated with IP67 level.
•2~3 times burn-in tests with 100% full toad for more than 24 hours.
•3 years warranty.
Model |
ZF -CV -150W-12V |
ZF -CV -150W-24V |
ZF -CV -150W-36V |
|||
Output | No load Voltage(N1) | 12.8V | 24.8V | 36.8V | ||
Rated Current | 12.5A | 6.25A | 4.16A | |||
Rated Power | 150W | 150W | 150W | |||
Ripple & Noise(N2) | 500mVp-p | 500mVp-p | 500mVp-p | |||
DC Voltage Range | 11-13V | 23-25V | 35-37V | |||
Current Accuracy (N3) | ≦105% | ≦105% | ≦105% | |||
Line Regulation | / | / | / | |||
Load Regulation | / | / | / | |||
Start-up Time (N4) | 200ms 80ms/230VAC ,500ms 80ms/110VAC | |||||
Keeping Time(Typ) | 10ms/230VAC,25ms/110VAC @ full load | |||||
Input | AC Voltage Range (N5) | 90-277VAC Or 130-420VDC | ||||
Frequency Range | 47-63Hz | |||||
PFC(Typ.) | PF>0.99 115VAC, PF>0.96 230VAC, PF>0.97VAC 277VAC@ Full Load | |||||
Efficiency(Typ.) | >89% | >90% | >90% | |||
AC(Typ.) | 4.05A/115VAC,2.02A/230VAC | |||||
Surge Current(Typ.) | Cold Start<50A /230VAC | |||||
Leakage Current | <0.75mA/300VAC | |||||
Protection | Over Current | 95-105% Constant Current Limited,Automatic Recover After Troubleshoot | ||||
Short Circuit | Hiccup Mode.Recover Automatically After Troubleshoot | |||||
Over Voltage | 15V | 27V | 39V | |||
Shut Down And Latch Off O/P Voltage,Restart On To Recover | ||||||
Over Temperature |
85℃±10℃,Start | |||||
Start Derating Over Temperature Protection When The Temperature Reach To 85℃,When The Temperature Is Up To 95℃,The Max Output Current Reduce To 40%,, It Called Output Current Typically (Refer To Over Temp. Deduction Curve.) | ||||||
Environment | Working Environment Temp. |
-40---+60℃ (Refer To Deduction Curve) |
||||
Humidity | 20-95%RH ,Non-condensing | |||||
Storage Temp.Humidity | -40-+80℃,10-95%RH | |||||
Max. Exotherm | +30℃ Open Environment Without Wind,The Max. Temperature On The Cover. | |||||
Anti-vibration | 10-500HZ,5G 12min/cycle,X,Y,Z is 72mins each. | |||||
Safety Standars & EMC |
Safety (N6) N6 |
EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010 | ||||
|
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
Insulation Resistance
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH | |||||
EMC Launch
|
Conform To EN55015,EN55022(CISPR22),Class B, EN61000-3-2 :2006+AA:2009 (≥70% Load) (The Customized Type can’t be sure.) |
|||||
EMC Immunity | EN55024-A , EN61000-3-3:2013 ;Fit EN 55015/EN 61000/EN 61547,CLASS B | |||||
Others | MTBF | 250K hrs min,MIL-HDBK-217F | ||||
Dimension | L208*W70*H40mm | |||||
Packing | 1450G/10pcs/15.5kg | |||||
Remark |
1.All parameters are measured at 25℃ and 230VAC If it don’t have special Note. 2.The oscilloscope is set to 20MHz bandwidth, A 0.1uF ceramic disk capacitor & 10uF electrolytic (low ESR) capacitor should be put across the output terminals during ripple & noise measure. 3.The accuracy include specification error, line regulation and load regulation. 4..Start-up time is measured under cold boot, Frequent on / off might impact start-up time. 5.It needs to deduction the output when the low voltage input , please refer to the static characteristic curve. 6.Safety & EMC Design :EN60598-1,CNS15233,GB700.1,FCC part18. 7.LED Power Supply must use with terminal equipment, due to EMC was impacted by whole fixture,so ,the terminal provider need to make EMC confirmation to whole fixture. |