Features
1. Universal input voltage design(90Vac~305Vac)
2. Output voltage and current parameters support the client settings
3. High power factor, low harmonics
4. High efficiency design (up to 88%)
5. Protection Design: Short-circuit, over-voltage, over-temperature
6. suitable for LED Lighting
7. IP65/IP67 grade,could be install in indoor and outdoor
8. 3years warranty
Parameters
Model No. | ZF-HLD-20-36 | ZF-HLD-20-43 | ZF-HLD-20-54 | ZF-HLD-20-65 | ZF-HLD-20-72 | ZF-HLD-20-88 | Customize | |
Output | No load voltage | 49VDC | 49VDC | 75VDC | 75VDC | 95VDC | 95VDC | |
DC current | 0.6A | 0.5A | 0.42A | 0.33A | 0.3A | 0.25A | customize | |
Output power | 22W | 22W | 23W | 22W | 22W | 22W | customize | |
Ripple and current | 4000mV | 4000mV | 4000mV | 4000mV | 4000mV | 4000mV | 4000mV | |
Output voltage range | 25-43VDC | 25-43VDC | 30-54VDC | 35-65VDC | 40-72VDC | 50-88VDC | customize | |
Efficiency(type) | ≥88% | ≥89% | ≥90% | ≥91% | ≥91% | ≥92% | ≥88% | |
Current error(Max) | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | |
Line regulation | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | |
Load regulation | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% | |
Start time note 3. | ≤≦1000ms,≤≦2000ms(full load)230VAC/115AC | |||||||
Hold time | 10ms full load 230VAC/115VAC | |||||||
input | Input voltage | 100-300VAC or 130-430VDC (When the AC input voltage is higher than 277VAC, the APFC is off and the power supply operates without PFC calibration) | ||||||
Frequency range | 47~63HZ | |||||||
PFC(Typ) | PF≥0.95 230VAC full load | |||||||
THD(Type) | <15% (standard for load lamps) | |||||||
AC current (Typ) | <0.3A/115VAC, <0.15A/230VAC, <0.1A/277VAC | |||||||
Inrush current(type) | Cold start<80A /230VAC | |||||||
Leakage current | <0.75MA/300VAC | |||||||
Protection design | Over current | 100% | ||||||
Short-circuit | Protection mode: hiccups, short circuit can be restored after removal | |||||||
Ouput short-circuit | When the output is shorted, the product enters the interval protection mode; when the short circuit is released, the product automatically resumes output | |||||||
Over-load | Maximum operating voltage limit | |||||||
Over-Temp. | The product's internal temperature monitoring point >90°C starts, reducing the output current as the temperature increases (the dimming product does not have this function) | |||||||
Environmental | Operating Temp. | -40---+55℃ | ||||||
Working humidity | 20-95%RH | |||||||
Storage temperature, humidity | -40---+80℃,20---95%RH | |||||||
Max temperature rise | +30°C No wind open environment, highest temperature point of shell | |||||||
vibration | 10-500HZ, 5G 12 minutes/cycle, 72 minutes for X, Y, and Z axes | |||||||
Safety and EMC | Safety standard Note4 | EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010 | ||||||
Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1KVAC | |||||||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH | |||||||
EMC | EN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009 | |||||||
EMI | EN55024-A , EN61000-3-3:2013 | |||||||
Lightning surge | L/N | L/N-FG,±3KV | ||||||
L-N | L-N,±5KV | |||||||
Cable Line | Input line | 3*0.75 Rubber line | ||||||
Output line | 2*0.75 /2*1 Rubber line | |||||||
Case | Full Aluminum | Silicone filling and filling |
Product Dimensions