30W small led street lighting driver constant current switching power suppy
Features:
1. Universal AC input voltage 90-277V(up to 305V)
2. high stability led driver,with high PFC and high efficiency
3. waterproof IP grade is IP67,we use silicon gel
4. protection design,short-circuit,ove-temperature,over-current,over-voltage.
5.Usually use for indoor or outdoor LED lighting
6.Parameter could be customized according to your led lighting.
Specification
Model | ZF-HLB-30-30 | ZF-HLB-30W-36 | ZF-HLB-30-50 | ZF-HLB-50-108 | customized | |||||
output | DC voltage | 30v | 36v | 50v | 108v | customized | ||||
Rated current | 1.1A | 0.9A | 0.6A | 0.3A | customized | |||||
Rated power | 30W | 30W | 30W | 30W | 30W | |||||
Ripple&noise | 150Mvp-p | 150Mvp-p | 200Mvp-p | 200Mvp-p | 200Mvp-p | |||||
voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | |||||
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
Load regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
Setup,rise time | 500ms,80ms/115VAC 500ms,80ms/230VAC | |||||||||
Hold up time | 16ms / 115VAC, 230VAC | |||||||||
Input | Input voltage | 90-277V | ||||||||
Frequency range | 47-63HZ | |||||||||
Power factory | PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load | |||||||||
Total Harmonic distortion | THD< 20% (@ load≧60% / 115VAC,230VAC; @ load≧75% / 277VAC) | |||||||||
Efficiency | 87% | 88% | 89% | 90% | ||||||
AC current | 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC | |||||||||
Inrush current | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||||
Leakage current | <0.75mA / 277VAC | |||||||||
Protection | Over current | Constant current limiting, recovers automatically after fault condition is removed | ||||||||
Short circuit | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
Over temperature | Shut down o/p voltage, re-power on to recover | |||||||||
Environment | Working Temp. | Tcase= -40 ~ +60℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) | ||||||||
Max.Case Temp. | Tcase= +80℃ | |||||||||
Working Humidity | 20 ~ 95% RH non-condensing | |||||||||
Temp.coefficient | ±0.03%/℃(0 ~ 60℃) | |||||||||
Vibration | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
Safty and standards | Safty standards | EN 61347-1:2008+A1:2011+A2:2013 ,EN 61347-2-13:2006, EN 62493:2010 | ||||||||
Isolaton resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||||
EMC emission | Compliance to EN55015, EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1 | |||||||||
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) |
Dimension size