Features
1. International input voltage(up to 305VAC)
2. With functions of active PFC
3. Efficiency reach to 89%
4. Protection design:short-circuit,over-voltage,over-current,over-temp.
5. IP67/IP65 design,for indoor and outdoor installation
6. 5 years warranty
7. Certification:CCC,CE,ROHS,TUV,SAA
Technical parameter
Model | ZF-HBG-100-36 | ZF-HBG-100-43 | ZF-HBG-100-48 | ZF-HBG-100-60 | Customized | |
Output | No-load voltage(MAX) | 37VDC | 44VDC | 55VDC | 66VDC | / |
Output current(Typ) | 3A | 2.5A | 2A | 1.62A | / | |
Output power(MAX) | 110W | 110W | 110W | 100W | / | |
Ripple and Noise Re.2 | 4000mV | 3000mV | 4000mV | 4000mV | MAX 4000mV | |
Output voltage range | 25-36VDC | 25-43VDC | 30-48VDC | 40-60VDC | / | |
Efficiency(Typ) | ≥90% | ≥90% | ≥91% | ≥91% | ≥90% | |
Current error(MAX) | ±2% | ±2% | ±2% | ±2% | ±2% | |
Line regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
Load regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
Start time Re.3 | ≤1500ms,≤3000ms(full load)230VAC/115AC | |||||
Keep time(Typ) | 10msfull load 230VAC/115VAC | |||||
Input | Input voltage range | 100-300VAC or 130-430VDC | ||||
Frequency range | 47-63HZ | |||||
Power factor(Typ) | PF≥0.95 230VAC full load | |||||
THD(Typ) | <20%(Refer to led Lighting parameter) | |||||
AC current(Typ) | <1.4A/115VAC, <0.8A/230VAC, <0.6A/277VAC | |||||
Surge current(Typ) | Cold start<50A /230VAC | |||||
Leakage current | <0.75MA/300VAC | |||||
Protection | Over-current | 100% | ||||
Short-circuit | Protect mode:Hi-cup,It can be recovered by itself after short-circuit removal | |||||
Over-load | Maximum operating voltage limit | |||||
Over-Temp. | Start up after temperature monitoring point is more than 90 ℃, reduce output current with increasing temperature (dimmer product does not have this function) | |||||
Environment | Operating Temp. | -40---+60℃ | ||||
Operating Humidity | 20-95%RH | |||||
Storage temperature, humidity | -40-+60℃,20-95%RH | |||||
Max temperature rise | +30℃ Non-wind open environment, maximum temperature point of shell | |||||
vibration resistance | 10-500HZ,5G 12 Min/Cycle,72 minutes each for the XMY Z axis | |||||
Safety and EMC | Safety specification note 5 | EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010 | ||||
withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1KVAC | |||||
Insulation impedance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH | |||||
EMI | EN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009 | |||||
EMC | EN55024-A , EN61000-3-3:2013 | |||||
Lightning surge | L/N-G | L/N-FG,±6KV | ||||
L-N | L-N,±5KV | |||||
Cables | rubber covered wire | Input line 3*0.75² | ||||
rubber covered wire | Output line 2*0.75² | |||||
case | Full aluminum case | Silica gel filling |
Dmensions
1. What is the warranty of the driver?
-- It's 3-5 years warranty
2 .What is MOQ of the led driver?
--1pcs
3.Can we get samples for testing?
-- Yes,sample order welcomed.
4.What is delivery of the sample and bulk order?
-- 5 working days for samples, 10-15days for the bulk order after payment down.
5.What is the payment?
--Paypal,T/T in advance,western Union,visa,credit card,30% deposit,70% before delivery.
6.How to delvery the samples and bulk order goods?
-by DHL,UPS,Fedex,TNT,By sea depend on your requirement.
Any interest item,welcome to contact with me.More information will be sent to you within 24 hours.