150W round shape UFO constant current LED driver 36-48V
Features:
Tehnical parameter:
Model | ZF-HBG-150-36 | ZF-HBG-150-42 | ZF-HBG-150-48 | ZF-HBG-150-54 | Customized | |
Output | No-load voltage(MAX) | 37VDC | 43VDC | 49VDC | 55VDC | / |
Output current(Typ) | 4.2A | 3.6A | 3.15A | 2.8A | / | |
Output power(MAX) | 153W | 153W | 153W | 153W | / | |
Ripple and Noise Re.2 | 300mV | 300mV | 300mV | 300mV | MAX 4000mV | |
Output voltage range | 25-36VDC | 25-42VDC | 25-48VDC | 38-54VDC | / | |
Efficiency(Typ) | ≥89% | ≥89% | ≥90% | ≥90% | ≥90% | |
Current error(MAX) | ±2% | ±2% | ±2% | ±2% | ±2% | |
Line regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
Load regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
Start time Re.3 | ≤800ms,≤1500ms(full load)230VAC/115AC | |||||
Keep time(Typ) | 10ms full load 230VAC/115VAC | |||||
Input | Input voltage range | 100-300VAC or 130-430VDC | ||||
Frequency range | 47-63HZ | |||||
Power factor(Typ) | PF≥0.97 230VAC full load | |||||
THD(Typ) | <20%(Refer to led Lighting parameter) | |||||
AC current(Typ) | <1.4A/115VAC, <0.8A/230VAC, <0.6A/277VAC | |||||
Surge current(Typ) | Cold start<50A /230VAC | |||||
Leakage current | <0.75MA/300VAC | |||||
Protection | Over-current | 100% | ||||
Short-circuit | Protect mode:Hi-cup,It can be recovered by itself after short-circuit removal | |||||
Over-load | Maximum operating voltage limit | |||||
Over-Temp. | Start up after temperature monitoring point is more than 90 ℃, reduce output current with increasing temperature (dimmer product does not have this function) | |||||
Environmet | Operating Temp. | -40---+60℃ | ||||
Operating Humidity | 20-95%RH | |||||
Storage temperature, humidity | -40-+60℃,20-95%RH | |||||
Max temperature rise | +30℃ Non-wind open environment, maximum temperature point of shell | |||||
vibration resistance | 10-500HZ,5G 12 Min/Cycle,72 minutes each for the XMY Z axis | |||||
Safety and EMC | Safety specification note 5 | EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010 | ||||
withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1KVAC | |||||
Insulation impedance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH | |||||
EMI | EN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009 | |||||
EMC | EN55024-A , EN61000-3-3:2013 | |||||
Lightning surge | L/N-G | L/N-FG,±6KV | ||||
L-N | L-N,±5KV | |||||
Cables | rubber covered wire | Input line 3*1² | ||||
rubber covered wire | Output line 2*1² | |||||
case | Full aluminum case | Silica gel filling | ||||
Others | MTBF | ≥150Khrs MIL-HDBK-217F(25℃) | ||||
Main body size | D151.68*H66.5mm | |||||
weight | ||||||
Remarks | 1. If not specified, all specifications are entered at 230 VAC. The measurements were carried out at 25 ℃ ambient temperature. 2. Ripple and noise measurement method: using a 0.5mm twisted-pair wire, the terminal should parallel the capacitance of 0.1uf and 47uf, and measure it under the 20MHZ bandwidth. 3. The start up time is measured under the start of the cooler, and the frequent switching machine may change the start up time. 4. Safety Design TUVEN 61347-1 en 61347-2-13 IECP en 60968-1.2004 A1: 2006 5. The power supply is considered to be a combination of a component and a terminal device. Because the EMC is affected by the complete set of devices, the terminal equipment manufacturer is required to make a EMC confirmation of the complete device. |
Dimension Size