Specifications
Brand Name :
Wayeal
Model Number :
LC3200
Certification :
ISO, CE
Place of Origin :
Anhui, China
MOQ :
1
Price :
Negotiation
Payment Terms :
L/C, T/T
Supply Ability :
30-40 Units Per Month
Delivery Time :
30 days
Packaging Details :
Wooden Case
Product Name :
HPLC Liquid Chromatography Instrument
Detector :
ELSD/FLD/RID/UVD/DAD
Working Power Supply :
220V, 50Hz
Ambient Temperature :
10~40°C
Relative Humidity :
20~85%
Flow Rate Range :
0.001~10.000mL/min
Description

HPLC Cromatografía Fully Automatic High Performance Liquid Chromatography Instrument

Description of High Performance Liquid Chromatography Instrument

High performance liquid chromatography is basically a highly improved form of column chromatography. Instead of a solvent being allowed to drip through a column under gravity, it is forced through under high pressures of up to 400 atmospheres. That makes it much faster.

It also allows you to use a very much smaller particle size for the column packing material which gives a much greater surface area for interactions between the stationary phase and the molecules flowing past it. This allows a much better separation of the components of the mixture.

The other major improvement over column chromatography concerns the detection methods which can be used. These methods are highly automated and extremely sensitive.

Technical Data of High Performance Liquid Chromatography Instrument

Manufacturer: Wayeal
Product Name: Liquid Chromatography Instrument
Working Power Supply 220V, 50Hz
Ambient Temperature 10~40°C
Relative Humidity 20~85%
Qualitative Repeatability ≤0.2%
Quantitative Repeatability ≤0.4%
High Pressure Constant Flow Pump
Flow Rate Range 0.001~10.000mL/min
Setting Step 0.001mL/min
Pressure Range 0~42MPa
Pressure Pulsation 0.1MPa
Flow Rate Set Error ±0.2%
Flow Rate Stability RSD≤0.06%
Gradient Error ±1%
Column Oven
Temperature Control Range 4~85°C
Temperature Stability ±0.02°C
Temperature Setting Resolution 0.1°C
Autosampler
Injection Volume Repeatability <0.5%RSD
Linearity >0.9999
Cross Contamination <0.002%
Injection Volume Accuracy Error ±1%
Sample Positions 120
Injection Volume 1~100μL
UV Detector
Baseline Noise ≤2.0*10-6Au
Baseline Drift ≤1*10-5Au/h
Mini Detection Concentration ≤3.0*10-9g/mL (naphthalene/methanol)
Spectral Range 188~900nm
Wavelength Error ≤±0.1nm
Wavelength Repeatability ≤±0.1nm
Linearity Range ≥103
DA Detector
Baseline Noise ≤4*10-5Au
Baseline Drift ≤3*10-5Au/h
Mini Detection Concentration ≤2*10-8g/mL
Spectral Range 190~800nm
Wavelength Error ≤±0.1nm
Wavelength Repeatability ≤±0.1nm
Linearity Range ≥ 104
ELS Detector
Baseline Noise ≤ 0.0037mV
Baseline Drift ≤ 0.0026mV/30min
Evaporation Gas Flow Range (0 ~ 3) SLM
Atomization Temperature Range Room temperature ~ 90℃
Evaporation Temperature Range Room temperature~110℃
Detection Chamber Temperature Range Room temperature~60℃
Input Air Pressure (4 ~ 7) bar
FL Detector
Baseline Noise ≤ 5×10-6 FU
Baseline Drift ≤ 2 × 10-5 FU/30min
Spectral Range (200 ~ 650) nm
Wavelength Error ± 0.1 nm
Linearity Range ≥ 104
RI Detector
Detection Range 0.25 ~ 512 μRIU
Linearity Range ≥ 600 μRIU
Response Time 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec;
Cell Volume 8μL


Performance of High Performance Liquid Chromatography Instrument

1. Mainstream split design

2. Split pump head with custom one-piece check valve;

3. Dynamic compensation technology with reduced flow fluctuations to ensure flow accuracy and stability; (patented)

4. Active flushing function of plunger rod;

5. With wavelength scanning and dual wavelength detection function;

6. High pressure pump with two-stage suspension floating drive technology, the use of drive suspension technology, combined with the import pump head of the suspension art plugs rod design, to extend the service life of the seal, reduce the user's use costs.

Applications of High Performance Liquid Chromatography Instrument

Determination of Aflatoxin B and G groups, Nutrients, Additives, Aflatoxin M, Heterotrophic trichothecene, Penicillin, Erythrostenone, Deoxynivalenol and its acetylated derivatives, Ochratoxin A, T-2 toxin, Fumonisins in food.
Fully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPaFully Automatic High Performance Liquid Chromatography Instrument 42MPa




Send your message to this supplier
Send Now

Fully Automatic High Performance Liquid Chromatography Instrument 42MPa

Ask Latest Price
Watch Video
Brand Name :
Wayeal
Model Number :
LC3200
Certification :
ISO, CE
Place of Origin :
Anhui, China
MOQ :
1
Price :
Negotiation
Contact Supplier
video
Fully Automatic High Performance Liquid Chromatography Instrument 42MPa
Fully Automatic High Performance Liquid Chromatography Instrument 42MPa
Fully Automatic High Performance Liquid Chromatography Instrument 42MPa
Fully Automatic High Performance Liquid Chromatography Instrument 42MPa
Fully Automatic High Performance Liquid Chromatography Instrument 42MPa

Anhui Wanyi Science and Technology Co., Ltd.

Verified Supplier
3 Years
anhui, hefei
Since 2003
Business Type :
Manufacturer, Exporter
Total Annual :
50 Million-100 Million
Employee Number :
1300~1500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement