Wayeal IC System Machine Ion Chromatography Instrument for Anions Cations Analysis
Introduction of Ion Chromatography Instrument
Ion chromatography instrument is a type of high performance liquid chromatograph, so it is also known as high performance ion chromatography (HPIC) or modern ion chromatography. IC systems can analyze particles such as anions, cations, organic salts, and proteins. They are used in environmental, manufacturing, food, pharmaceutical, and chemical industries.
Parameters of Ion Chromatography Instrument
IC Ion Chromatography Instrument System for Anion Cation Analysis | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | (0.001~10.000)mL/min |
Pump Head Pressure Resistance | (0 ~ 35) MPa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤0.0002μg/mL |
Minimum Detection Concentration (Li) | ≤0.0001μg/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5mL standard sample bottle) |
Repeatability | Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5uL) |
Syringe Size | Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size | Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow Rate Range | 0.001 to 3.000ml/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21MPa (3000psi) |
Gradient Accuracy | 1.5% |
Performance of Ion Chromatography Instrument
1. The dual operation mode of the touch screen and PC counter control software enables the simultaneous output and execution of operating instructions
2. Graphical counter-control interface, humanized operation process, which allows qualitative and quantitative analysis of negative peaks of the system, improves the efficiency and accuracy of peak determination and ensures the efficiency and accuracy of data processing.
3. Pre-heating of the drench solution prior to the injection valve to avoid negative effects such as poor reproducibility and peak spread due to temperature differences.
4. 7.0" high brightness LCD touch GUI controller, synchronised with the chromatography workstation, allows full operation of the instrument and spectrogram display etc.
5. Electrolytic self-regenerating membrane inhibition method, reagent-free design, no additional acid and alkali addition, no peristaltic pump regeneration.
Industry Application
Environment, food, medicine, agriculture, grain and oil, and chemical industry