IC6210 Integrated Ion Chromatography Instruments with Conductivity Detector
Introduction of Ion Chromatography Instrument
Ion chromatography, a form of liquid chromatography, measures concentrations of ionic species by separating them based on their interaction with a resin. Ionic species separate differently depending on species type and size. Sample solutions pass through a pressurized chromatographic column where ions are absorbed by column constituents. As an ion extraction liquid, known as eluent, runs through the column, the absorbed ions begin separating from the column. The retention time of different species determines the ionic concentrations in the sample.
Features of Ion Chromatography Instrument
1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time
5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.
Parameters of Ion Chromatography Instrument
In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector | |
System Parameter | |
Qualitative Repeatability | ≤0.5% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | (0.001~10.000)mL/min |
Pump Head Pressure Resistance | (0 ~ 35) Mpa |
Flow Rate Setting Inaccuracy | <0.1% |
Flow Stability | <0.1% |
Pressure Display Accuracy | 0.01Mpa |
Pressure Pulsation | <0.5% |
Conductivity Detector | |
Baseline Noise | ≤0.1%FS |
Baseline Drift | ≤0.5%FS |
Minimum Detectable Concentration (Cl) | ≤0.0002μg/mL |
Minimum Detection Concentration (Li) | ≤0.0001μg/mL |
Conductivity Cell Volume | ≤ 0.6μL |
Conductivity Detection Range | 0-15000μS/cm |
Detector Resolution | 0.00238nS/cm |
Conductivity Cell Temperature Setting Error | ±0.01°C |
Resolution of Conductivity Cell Temperature Display | 0.001°C |
Suppressor | |
Constant Current Source Range | 0-500mA in 0.1mA increments |
Column Oven | |
Temperature Range | Room temperature +5°C~85°C |
Control Temperature Stability | ≤ 0.1°C |
Autosampler | |
Number of Sample Vials | ≥ 120 (1.5mL standard sample bottle) |
Repeatability | Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5μL) |
Syringe Size | Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size | Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity | >0.999 |
Cross-contamination | <0.01% |
Eluent Generator | |
Flow Rate Range | 0.001 to 3.000mL/min |
Eluent Concentration Range | KOH, MSA-0.1 to 100mM |
Concentration Accuracy | 0.1mM |
Original Concentration of Electrolyte | 25% KOH/MSA |
Volume of Electrolyte | 1000mL |
Maximum Working Pressure | 21Mpa (3000psi) |
Gradient Accuracy | 1.5% |
Industry Application
It can be used for the detection and analysis of anions (e.g. F- , Cl- , Br- , BrO3- , NO3- , NO2- , SO42- , PO43- , disinfection by-products, etc.) and cations (e.g. Li+ , Na+ , NH4+ , K+ , Mg2+ , Ca2+ , etc.).