FLD Detector High Pressure Liquid Chromatography Machine in Pesticide Residue Analysis
Description of Liquid Chromatography Instrument
High-performance liquid chromatography or high-pressure liquid chromatography (HPLC) is a chromatographic method that is used to separate a mixture of compounds in analytical chemistry and biochemistry so as to identify, quantify or purify the individual components of the mixture. In very small amounts, the sample mixture to be separated and tested is sent into a stream of mobile phase percolating via a column. The mixture moves through the column at varying velocities and interacts with the sorbent, also known as the stationary phase.
Parameters of Liquid Chromatography Instrument
FLD Detector High Pressure Liquid Chromatography Machine in Pesticide Residue Analysis | |
Physical Specification | |
Power Requirements | 220V,50HZ |
Ambient Temperature | 4-40℃ |
Ambient Humidity | 20-85% relative humidity(non-condensing) |
System | |
Qualitative repeatability(Retention time) | RSD≤0.3% |
Quantitative repeatability(Area) | RSD≤0.6% |
Pump | |
Flow Rate Range | 0.0001-10.000mL/min( increments :0.0001 mL/min) |
Max Operating Pressure | 42MPa |
Pressure Pulsation | <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow Accuracy | ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol) |
Flow Precision | RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol) |
Gradient Accuracy | ±1% |
Column Oven | |
Temperature Setting Range | 5 °C ~ 85 °C |
Temperature Stability | ≤0.2°C/h |
Temperature Controlling Precision | ±0.1 °C |
Autosampler | |
Injection Volume Precision | <0.25%RSD( full loop) ; <0.5%RSD( partial loop) ; <1%RSD( no waste) |
Linearity | >0.999 |
Cross Contamination(Carry Over) | <0.01% |
Sample Capacity | 120 Samples( 1.5ml vials) |
Syringe | 250 μL( Standard, with 500μL,1000μL, 2500μL optionals) |
Sample Loop | 20μL( Standard, with 50μL, 100μL, 200μL optional) |
FLD Detector | |
Noise | 1×10-5Au |
Drift | 2×10-4Fu/30min |
LOD | 5.0×10-10g/mL (naphthalene/methanol) |
Wavelength Range | 200-650nm |
Wavelength Reproducibility | ±2 nm |
Linearity | ≥1.0×104 |
Features of Liquid Chromatography Instrument
1. Two optional modes: binary high pressure and quaternary low pressure
2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.
3. A variety of detectors available, such as DAD, ELSD and FLD.
4. Dual-wavelength detection, two wavelengths canbe detected at the same time.