Description of Ion Chromatography Instrument:
Ion Chromatography InstrumentThe ion chromatography instrument is a powerful and versatile analytical tool designed for the detection and quantification of ions and molecules in a wide range of sample types. With its advanced features and capabilities, this instrument is ideal for use in research, quality control, and process monitoring applications in a variety of industries, including pharmaceuticals, food and beverage, environmental analysis, and more.
Technical Parameters of Ion Chromatography Instrument:
Precise and Reliable Advanced Ion Chromatography Instrument for Scientific Analysis | |
---|---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Ion Chromatography Instrument:
The Ion Chromatography Instrument is highly versatile and can be used in a variety of occasions and scenarios. Some of these include: