Product Description of Ion Chromatography Instrument:
The Ion Chromatography Instrument is a highly accurate and reliable instrument that is well-suited for a wide range of analytical applications. With exceptional flow rate stability, injection volume flexibility, concentration accuracy, linearity, and pump pressure performance, it is a top-of-the-line instrument that will deliver accurate and reliable results every time.
Technical Parameters of Ion Chromatography Instrument:
IC6300 Ion Chromatography Instrument for Accurate Analysis of Nitrite in Food | |
---|---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Instrument:
The IC6300 is ideal for a wide range of applications, including the analysis of inorganic and organic ions in water, food, and beverages, as well as environmental and biological samples. It is also suitable for the determination of anions and cations in pharmaceuticals and chemicals.