Description of Ion Chromatography Instrument:
The Ion Chromatography Instrument is an excellent choice for anyone looking for accurate and reliable ion analysis. Its exceptional quantitative repeatability, concentration accuracy, and wide flow rate and injection volume ranges make it a versatile and dependable instrument for any laboratory. With its high-quality features, it can be used for various applications including environmental monitoring, food and beverage analysis, and quality control in different industries.
Technical Parameters of Ion Chromatography Instrument:
Fully PEEK Pump Ion Chromatography Instrument with Optional Detectors | |
---|---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Instrument:
The Wayeal IC6300 Ion Chromatography Instrument is suitable for a wide range of applications. It can be used in research laboratories, universities, and other academic institutions for the analysis of inorganic and organic ions. It can also be used in environmental monitoring, food and beverage analysis, and quality control in various industries.
The instrument is designed to work within a temperature range of 10~40°C, which makes it ideal for use in different climates and environments. Its high accuracy and precision make it a reliable tool for identifying and quantifying different ions in a variety of samples.