The conventional liquid chromatography columns independentlydeveloped by NovaChrom utilize uniform silica gel microspheres, combined withadvanced and stable bonding phase modification techniques, enabling the separationof analytes with different hydrophobicities. These columns have a wide range ofapplications and offer high cost-effectiveness.Thehybridseries adopt organic-inorganichybrid silica gel microspheres, combined with novel bonding technologies, suitable forapplications requiring awide pH range and various mobile phase systems
Specifications of NovaChrom Chromatography Column:
Product Name | C18 | PC18 | AQC18 | SC18 | C8 | Ph | PFP | NH2 | CN | Diol | Sil |
Bonded Phase | Octadecyl (ODS) | Octadecyl (ODS) | Octadecyl (ODS) | Octadecyl (ODS) | Octyl | Phenyl | Pentafluorophenyl | Aminopropyl | Cyano | glycol | None |
Matrix | Fully Porous Silica | ||||||||||
Particle Size | 3μm/5μm | 3μm/5μm | 5μm | 5μm | 5μm | 5μm | 5μm | 5μm | 5μm | 5μm | 5μm |
Pore Size | 120Å | 100Å | 120Å | 120Å | 120Å | 120Å | 100Å | 120Å | 120Å | 120Å | 120Å |
Surface Area | 350m²/g | 450m²/g | 300m²/g | 350m²/g | 350m²/g | 350m²/g | 450m²/g | 350m²/g | 350m²/g | 350m²/g | 350m²/g |
Carbon Load | 16% | 16% | 15% | 19% | 9% | 8% | 10% | 5% | 6% | 8% | 0% |
Endcapped | Yes | Yes | Yes | Yes | Yes | Yes | No | No | No | No | No |
pH Range | 1.5-9.5 | 1.5-9.0 | 1.5-9.0 | 1.5-11 | 2-8 | 2-8 | 2-8 | 2-8 | 2-8 | 2-8 | 2-8 |
Aqueous Compatibility | <95% Aqueous | 100% Aqueous | 100% Aqueous | <95% Aqueous | <95% Aqueous | <95% Aqueous | <95% Aqueous | <95% Aqueous | <95% Aqueous | <95% Aqueous | 100% Aqueous |
Column | Inforamtion | Specification | pH Range | Application |
Nova Atom C18 | Nova Atom™ C18 Column | 5um,4.6x250mm | 1.5-9.5 | GeneralApplications |
Nova Atom Pc18 | Nova Atom™ PC18 Column | 5um,4.6x250mm | 1.5-9.0 | Resistant to 100% aqueous phase ,High resolution,Preferred for analysis of alkaline substances |
Nova Atom Sc18 | Nova AtommSC18 Column | 5um.4.6x250mm | 1.5-11 | Widely used under broader pH range |
Nova Atom C8 | Nova Atom™M C8 Column | 5um.4.6x250mm | 2-8 | Analysis ofcompounds with weaker retention compared to C18 |
Nova Atom Ph | Nova Atomm Phenyl Column | 5um,4.6x250mm | 2-8 | Sugar sample analysis for reverse phase mode Analysis of hydrocarbon compounds for normal phase mode |
Nova Atom Nh2 | Nova AtomIM Amino Column | 5um,4.6x250mm | 2-7 | For analysis of aromatic compounds |
Nova Atom CN | Nova Atom™M Cyano Column | 5um,4.6x250mm | 2-11 | For analysis of hydrophobic, unsaturated and polar compounds |
Nova Atom Diol | Nova AtomIM Diol Column | 5um,4.6x250mm | 2-11 | Hilic mode, analysis of polarcompounds |