Mini Weighing Force Measuring Controller With Force Display And Force DO Output Mode
Example 1. Sending Weight Data ‘+00123.4kg’
Byte Field Name HEX Note
1 START 3D =
2 Weighing State 53 S
3 Data Name 4E N
4 Sign 2B +
5 Weight Value 30 0
6 Weight Value 30 0
7 Weight Value 31 1
8 Weight Value 32 2
9 Weight Value 33 3
10 Weight Value 2E .
11 Weight Value 34 4
12 Unit 6B k
13 SUM CC SUM=Byte1+Byte2+…+Byte12
14 END 0D <CR>
15 END 0A <LF>
Example 2. Sending Displayed Characters ‘ 2. dISP’
Byte Field Name HEX Note
1 START 3D =
2 Weighing State 53 S
3 Data Name 44 D
4 ID Code 64 d
5 Point Code 20
6 Displayed Characters 32 2
7 Displayed Characters 20 Space
8 Displayed Characters 64 d
9 Displayed Characters 49 I
10 Displayed Characters 53 S
11 Displayed Characters 50 P
12 ID Code 64 d
13 SUM 5E SUM=Byte1+Byte2+…+Byte12
14 END 0D <CR>
15 END 0A <LF>
Technical Specifiction:
Power Supply | AC24V±20% |
Display | 5 Red Led Digital Tubes for English&Digit Display |
Sampling Frequency | 1280Hz |
A/D Convert | 24-bit |
Keypad | 4 keys for Shortcut mode operation with key tone |
Excitation Voltage Output of Loadcell | DC5V |
Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
[mV]Signal Input Range | 0-19.5mV |
DO | 2 Normally Open Transistor Switch Outputs |
AO | 1Analog Signal Output: 4~20mA. |
Communication Port | COM1:RS232;COM2:RS485 |
Outline Dimension | 107 × 60 × 100 mm (W×H×D) |
Net Weight | Approx. 1.2kg |
IP Grade | IP65 |
Verfication Accuracy | 0.03% |
Static Weighing/Force Measuring Accuracy | 0.2%~.5~ |
Mini Weighing Force Measuring controller with force display and Force DO output mode
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu. Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. Display the previous option. |
【►】 | Cursor shifts left. Display the next option. |
【▲】 | Display the next interface or option. Digit input: +1 ( 0~9 loop). |
【▼】 | Display the previous interface or option. Digit input: -1 ( 0~9 loop). |
Quick Operation | |
【MENU】 【Ñ】 * |
|
【◄】 (【SET】) | Recipe parameters setting. |
【◄】 【ZERO】 【→0←】 * |
|
【▲】 【TARE】 【→T←】 * |
|
【ENT】 【G/N】 | Gross Weight / Net Weight display switch. |