Specifications
Brand Name :
Supmeter
Model Number :
BST106-B60[T]
Certification :
CE
Place of Origin :
China
MOQ :
1pcs
Price :
Negotiation
Payment Terms :
T/T, Western Union
Packaging Details :
1pcs/box
Power Supply :
DC24V
Analog Signal :
4-20mA
DO :
2
Outline Size :
107*60*100mm
Description

Weigh Display Setpoint Do Output Manual Totalizing Electronic Weighing Indicator

Main Applications
 Crane [Wheel Crane, Travelling Crane, Frame Crane, Bridge
Crane and so on] Overload Protection.
 Sound-light Pre-alarm for Weight High Limit.
 Delay-stop for Weight Higher Limit.
 Emergency-stop for Weight Highest Limit.
Main Features
 EMC design with high anti-jam for industrial environment.
 DC24V power input with reverse polarity protection.
 32-bit ARM CPU with 48MHz clock & high arithmetic speed.
 5 Red LED digital tubes for English&digit display.
 24-bit ∑-△ADC with internal resolution 1/1,000,000.
 High sampling frequency 640Hz.
 Special Anti-vibration Digital Filtering Algorithm for precise
weighing, stable display and rapid response.
 Auto Zero Tracking.
 Load Calibration & Data Calibration.
 Definable AO/COM[Communication Port].

Pictures

High Protecting Level Electronic Weighing Indicator With Led Display And Rs232High Protecting Level Electronic Weighing Indicator With Led Display And Rs232

No. Pin Description
LOADCELL Loadcell Port
Connection Mode 6-Wire 4-Wire
Internal Dip Switch S4 S4→【6-WIRE】

S4→【4-WIRE】

[Default Set]

1 SIG- Weighing Signal [mV] Input -. Weighing Signal [mV] Input -.
2 SIG+ Weighing Signal [mV] Input +. Weighing Signal [mV] Input +.
3 EXC- Excitation Voltage -. Excitation Voltage -.
4 SEN- Feedback Voltage -.
5 EXC+ Excitation Voltage + [DC9V]. Excitation Voltage + [DC9V].
6 SEN+ Feedback Voltage +.
7 SHD Shield Ground. Shield Ground.
POWER DC24V[±20%] Power Input Port
1 DC- DC Input -.
2 DC+ DC Input +.
The metal shell should be grounded directly. For separating the controller from the interference of the driving devices, the DC24V power supply of the controller should not be shared by the DO.


Sign Alarm Cause Solution
AD_ER ADC Failure. Replace the ADC module.
OV_AD Over ADC Range.

Force signal exceeds A/D conversion range.

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading force is too big.

OV_LD Force Value Overload Alarm.

Force Value>(Single-channel Force Capacity+9×Scale Division).

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading force is too big.

Refer to Parameter [102].

Resultant Force Overload Alarm.

Resultant Force>(Max. Resultant Force+9×Scale Division).

Refer to Parameter [102].

State Indication

LED light Description
[RUN]

OFF: Real-time Force Value tracking display state.

ON: Peak Value Detecting Result holding display state [Peak Value Detecting Process Finished].

Blinking: Peak Value tracking display state [In Peak Value Detecting Process].

[AL1]

Real-time Resultant Force or Resultant Force Peak Value Upper Limit Alarm.

Refer to Parameters [200]&[202].

[AL2]

Real-time Resultant Force or Resultant Force Peak Value Lower Limit Alarm.

Refer to Parameters [201]&[202].

Installation

High Protecting Level Electronic Weighing Indicator With Led Display And Rs232
High Protecting Level Electronic Weighing Indicator With Led Display And Rs232
Send your message to this supplier
Send Now

High Protecting Level Electronic Weighing Indicator With Led Display And Rs232

Ask Latest Price
Brand Name :
Supmeter
Model Number :
BST106-B60[T]
Certification :
CE
Place of Origin :
China
MOQ :
1pcs
Price :